Table 10. Diagnostic LED POST Code Decoder, DIMMs failed Memory
UPC - 735858210980
View all Intel SR1690WB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
0x22h 0x23h 0x24h 0x25h 0x26h 0x27h 0x28h 0xE4h 0xE6h 0xE8h 0xE9h 0xEAh 0xEBh 0xECh 0xEDh 0xEBh Table 10. Diagnostic LED POST Code Decoder 0 0 1 0 0 0 1 0 Reading configuration data from memory (SPD on FBDIMM) 0 0 1 0 0 0 1 1 Detecting presence of memory 0 0 1 0 0 1 0 0 Programming timing parameters in the memory controller 0 0 1 0 0 1 0 1 Configuring memory parameters in the memory controller 0 0 1 0 0 1 1 0 Optimizing memory controller settings 0 0 1 0 0 1 1 1 Initializing memory, such as ECC init 0 0 1 0 1 0 0 0 Testing memory 1 1 1 0 0 1 0 0 BIOS cannot communicate with DIMM (serial channel hardware failure 1 1 1 0 0 1 1 0 DIMM(s) failed Memory iBIST or Memory Link Training failure 1 1 1 0 1 0 0 0 No memory available (system halted) 1 1 1 0 1 0 0 1 Unsupported or invalid DIMM configuration (system halted) 1 1 1 0 1 0 1 0 DIMM training sequence failed (system halted) 1 1 1 0 1 0 1 1 Memory test failed (system halted) 1 1 1 0 1 1 0 0 Unsupported or invalid DIMM configuration (system halted) 1 1 1 0 1 1 0 1 Unsupported or invalid DIMM configuration (system halted) 1 1 1 0 1 0 1 1 DIMM with corrupted SPD data detected (system halted) Intel® Server System SR1690WB Service Guide 75