Intel SR1690WB Service Guide - Page 98

Fixed Media, Removable Media, Boot Device Selection BDS, Entered the Boot Device

Page 98 highlights

Table 10. Diagnostic LED POST Code Decoder 0xABh 1 0xACh 1 0xADh 1 Fixed Media 0xB0h 1 0xB1h 1 0xB2h 1 0 1 0 0 1 0 0 1 0 0 1 1 0 1 1 0 1 1 0xB3h 1 0 1 1 0xB4h 1 0 1 1 Removable Media 0xB8h 1 0 1 1 0xB9h 1 0 1 1 0xBAh 1 0 1 1 0xBCh 1 0 1 1 0xBDh 1 0 1 1 Boot Device Selection (BDS) 0xD0 1 1 0 1 0xD1 1 1 0 1 0xD2 1 1 0 1 0xD3 1 1 0 1 0xD4 1 1 0 1 1 0 1 1 Clearing serial port buffer 1 1 0 0 Enabling serial port 1 1 0 1 Reserved for serial port 0 0 0 0 Resetting fixed media device 0 0 0 1 Disabling fixed media device 0 0 1 0 Detecting presence of a fixed media device (IDE hard drive detection, and so on) 0 0 1 1 Enabling / configuring a fixed media device 0 1 0 0 Reserved for fixed media 1 0 0 0 Resetting removable media device 1 0 0 1 Disabling removable media device 1 0 1 0 Detecting presence of a removable media device (IDE CDROM detection, etc.) 1 1 0 0 Enabling / configuring a removable media device 1 1 0 1 Reserved for removable media device 0 0 0 0 Entered the Boot Device Selection phase (BDS) 0 0 0 1 Return to last good boot device 0 0 1 0 Set up boot device selection policy 0 0 1 1 Connect boot device controller 0 1 0 0 Attempt flash update boot mode 80 Intel® Server System SR1690WB Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154

80
Intel
®
Server System SR1690WB Service Guide
0xABh
1
0
1
0
1
0
1
1
Clearing serial port buffer
0xACh
1
0
1
0
1
1
0
0
Enabling serial port
0xADh
1
0
1
0
1
1
0
1
Reserved for serial port
Fixed Media
0xB0h
1
0
1
1
0
0
0
0
Resetting fixed media
device
0xB1h
1
0
1
1
0
0
0
1
Disabling fixed media
device
0xB2h
1
0
1
1
0
0
1
0
Detecting presence of a
fixed media device (IDE
hard drive detection, and
so on)
0xB3h
1
0
1
1
0
0
1
1
Enabling / configuring a
fixed media device
0xB4h
1
0
1
1
0
1
0
0
Reserved for fixed media
Removable Media
0xB8h
1
0
1
1
1
0
0
0
Resetting removable
media device
0xB9h
1
0
1
1
1
0
0
1
Disabling removable
media device
0xBAh
1
0
1
1
1
0
1
0
Detecting presence of a
removable media device
(IDE CDROM detection,
etc.)
0xBCh
1
0
1
1
1
1
0
0
Enabling / configuring a
removable media device
0xBDh
1
0
1
1
1
1
0
1
Reserved for removable
media device
Boot Device Selection (BDS)
0xD0
1
1
0
1
0
0
0
0
Entered the Boot Device
Selection phase (BDS)
0xD1
1
1
0
1
0
0
0
1
Return to last good boot
device
0xD2
1
1
0
1
0
0
1
0
Set up boot device
selection policy
0xD3
1
1
0
1
0
0
1
1
Connect boot device
controller
0xD4
1
1
0
1
0
1
0
0
Attempt flash update boot
mode
Table 10. Diagnostic LED POST Code Decoder