PREPARATIONS FOR OPERATION Synchronizing with the Time Code of the IEEE1394 (DV)-Connected Master Unit You can synchronize the time code when performing multi-camera recording. The internal time code generator will be synchronized with the time code in the signal input from the IEEE1394 terminal. After synchronization (slave lock), the internal time code generator continues to run even if the IEEE1394 cable is disconnected. Master unit Slave unit MACRO MACRO VF BRIGHT USER 1 USER 2 USER 3 ND FILTER 2 1 MENU STATUS WHT.BAL AUTO AUTO AUDIO CH-1 LEVEL CH-2 ON OFF POWER REC Slide the IEEE1394 switch to the [DV] side. IEEE1394 terminal IEEE1394 cable VF BRIGHT USER 1 USER 2 USER 3 ND FILTER 2 1 MENU STATUS WHT.BAL AUTO AUTO AUDIO CH-1 LEVEL CH-2 ON OFF POWER REC IEEE1394 terminal Slide the IEEE1394 switch to the [DV] side. You can use the GY-HD200U or GY-HD201E as a slave unit. You cannot use the GY-HD200E as a slave unit. Connections Connect the master unit and the slave unit with an IEEE1394 cable. Settings and Operations • Master unit (GY-HD200U/GY-HD200E/GY-HD201E/GYHD250U/GY-HD251E/GY-HD100, 101 series/GY-HD110, 111 series) 1. Set the IEEE1394 switch on the left side to [DV]. 2. Set to Camera mode. 3. Set the recording format to DV-60I or DV50I. 4. Set the TC GENE. switch to [FREE]. • Slave unit (GY-HD200U/GY-HD201E) 1. Set the IEEE1394 switch on the left side to [DV]. 2. Set to VTR mode. 3. Check that the camera image from the master unit is input. 4. Set the TC GENE. switch to [FREE] and the TC DISPLAY switch to [TC]. 5. Set to STOP mode or EJECT mode. 6. Press the STOP button for 1 second. • The DV input time code data from the IEEE1394 terminal is displayed in the status display. (When status is in magnified size, characters are displayed.) 7. Press the USER1 button to begin slave lock. (To skip slave lock, press the USER3 button and clear the status display.) Status display DTCG 00 : 00 : 00 : 00 TC SLAVE LOCK ? EXECUTE CANCEL USER1 USER3 8. Check that the time code that is synchronized with the master unit is running. 9. Disconnect the IEEE1394 cable. 10.The slave unit finally returns to Camera mode. MEMO „ Slave lock cannot be performed in the following instances. • Slave unit is in CAMERA mode • Slave unit is in VTR mode and there is no DV signal • The TC GENE. switch on the slave unit is not set to FREE • The slave unit is GY-HD200E • HDV format „ If slave lock is performed in DV format and is then switched to HDV format, frame digit may deviate. „ If power is turned off, slave lock is disabled. Perform slave lock operation again. „ Slave lock cannot be performed for UB (User's bit). „ If the frame rate for the master unit and slave unit is not synchronized, it will not run properly. Synchronize frame rate before using. „ If DROP/NON DROP is not synchronized, it will not run properly. Synchronize DROP/NON DROP before using. 48 Screen Adjustment Viewfinder Adjustment LCD monitor direction, angle, screen brightness, etc. can be adjusted. Adjusting the Direction and Angle of the LCD monitor • With the LCD door in the open condition, rotate the LCD door. • It can be turned 180° in upward direction and 90° in downward direction. When turned 180° upward direction, the LCD monitor can be viewed from the lens side (vertically inverted image). PEAKING volume LCD BRIGHT button 180° up LCD - BRIGHT + AUDIO SELECT CH-1 CH-2 AUTO MANU CAM/VTR TC DISPLAY TC UB GENE. FREE REC REGEN 90° down LCD lock release lever Adjusting the LCD monitor • PEAKING: Adjusts the contour of the LCD monitor. • LCD BRIGHT: Adjusts the brightness of the LCD monitor. Adjustments are made on the LCD/VF[2/4] menu screen. X See page 87. • LCD MIRROR MODE: Sets the LCD monitor to display mirrored images when shooting facing the subject. Adjustments are made on the LCD/VF[4/4] menu screen. X See page 89. • LCD CONTRAST: Adjusts the contrast of the LCD monitor. • BLACK & WHITE: Sets the LCD monitor and viewfinder to black and white display. Direction of the Viewfinder Adjust the position and angle of the viewfinder. Diopter Adjustment Rotate the eyepiece focusing ring until the viewfinder screen image is clearly visible. Adjustment of the Viewfinder Screen • PEAKING: Adjusts the contour of the LCD monitor and the viewfinder screen. • VF BRIGHT: Adjusts the brightness of the viewfinder screen. Eyepiece focusing ring Eyepiece VF BRIGHT volume PEAKING volume Sliding securing ring Viewfinder mount base Adjustments are made on the LCD/VF[4/4] menu screen. X See page 89. • VF CONTRAST: Adjusts the contrast of the viewfinder screen. • BLACK & WHITE: Sets the LCD monitor and viewfinder to black and white display. MEMO The screen size of the viewfinder can be changed by selecting the desired size with the ASPECT item on the VIDEO FORMAT[1/2] menu screen (4:3 or 16:9). 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117

PREPARATIONS FOR OPERATION
48
Synchronizing with the
Time Code of the IEEE1394
(DV)-Connected Master Unit
You can synchronize the time code when performing multi-camera recording. The internal time code generator will be synchro-
nized with the time code in the signal input from the IEEE1394 terminal. After synchronization (slave lock), the internal time code
generator continues to run even if the IEEE1394 cable is disconnected.
You can use the GY-HD200U or GY-HD201E as a slave unit.
You cannot use the GY-HD200E as a slave unit.
Connections
Connect the master unit and the slave unit with an IEEE1394
cable.
Settings and Operations
Master unit (GY-HD200U/GY-HD200E/GY-HD201E/GY-
HD250U/GY-HD251E/GY-HD100, 101 series/GY-HD110,
111 series)
1.
Set the IEEE1394 switch on the left side to [DV].
2.
Set to Camera mode.
3.
Set the recording format to DV-60I or DV50I.
4.
Set the TC GENE. switch to [FREE].
Slave unit (GY-HD200U/GY-HD201E)
1.
Set the IEEE1394 switch on the left side to [DV].
2.
Set to VTR mode.
3.
Check that the camera image from the master unit is input.
4.
Set the TC GENE. switch to [FREE] and the TC DISPLAY
switch to [TC].
5.
Set to STOP mode or EJECT mode.
6.
Press the STOP button for 1 second.
The DV input time code data from the IEEE1394 termi-
nal is displayed in the status display. (When status is in
magnified size, characters are displayed.)
7.
Press the USER1 button to begin slave lock.
(To skip slave lock, press the USER3 button and clear
the status display.)
8.
Check that the time code that is synchronized with the
master unit is running.
9.
Disconnect the IEEE1394 cable.
10.
The slave unit finally returns to Camera mode.
MEMO
Slave lock cannot be performed in the following
instances.
Slave unit is in CAMERA mode
Slave unit is in VTR mode and there is no DV signal
The TC GENE. switch on the slave unit is not set to
FREE
The slave unit is GY-HD200E
HDV format
If slave lock is performed in DV format and is then
switched to HDV format, frame digit may deviate.
If power is turned off, slave lock is disabled. Perform
slave lock operation again.
Slave lock cannot be performed for UB (User’s bit).
If the frame rate for the master unit and slave unit is not
synchronized, it will not run properly. Synchronize frame
rate before using.
If DROP/NON DROP is not synchronized, it will not run
properly. Synchronize DROP/NON DROP before using.
Master unit
Slave unit
IEEE1394 cable
IEEE1394 terminal
IEEE1394 terminal
Slide
the
IEEE1394
switch to the [DV] side.
Slide
the
IEEE1394
switch to the [DV] side.
DTCG
TC
SLAVE
LOCK
?
EXECUTE
USER1
00 : 00 : 00 : 00
CANCEL
USER3
Status display
49
Screen Adjustment
LCD monitor direction, angle, screen brightness, etc. can be
adjusted.
Adjusting the Direction and Angle of the
LCD monitor
With the LCD door in the open condition, rotate the LCD
door.
It can be turned 180° in upward direction and 90° in down-
ward direction.
When turned 180° upward direction, the LCD monitor can
be viewed from the lens side (vertically inverted image).
Adjusting the LCD monitor
PEAKING:
Adjusts the contour of the LCD monitor.
LCD BRIGHT:
Adjusts the brightness of the LCD monitor.
Adjustments are made on the LCD/VF[2/4] menu screen.
X
See page 87.
LCD MIRROR MODE:
Sets the LCD monitor to display mirrored images when
shooting facing the subject.
Adjustments are made on the LCD/VF[4/4] menu screen.
X
See page 89.
LCD CONTRAST:
Adjusts the contrast of the LCD monitor.
BLACK & WHITE:
Sets the LCD monitor and viewfinder to black and white
display.
Viewfinder Adjustment
Direction of the Viewfinder
Adjust the position and angle of the viewfinder.
Diopter Adjustment
Rotate the eyepiece focusing ring until the viewfinder screen
image is clearly visible.
Adjustment of the Viewfinder Screen
PEAKING:
Adjusts the contour of the LCD monitor and the viewfinder
screen.
VF BRIGHT:
Adjusts the brightness of the viewfinder screen.
Adjustments are made on the LCD/VF[4/4] menu screen.
X
See page 89.
VF CONTRAST:
Adjusts the contrast of the viewfinder screen.
BLACK & WHITE:
Sets the LCD monitor and viewfinder to black and white
display.
MEMO
The screen size of the viewfinder can be changed by
selecting the desired size with the ASPECT item on the
VIDEO FORMAT[1/2] menu screen (4:3 or 16:9).
-
+
PEAKING volume
LCD BRIGHT
button
LCD lock release lever
180° up
90° down
Eyepiece focusing ring
VF BRIGHT volume
Eyepiece
PEAKING volume
Sliding securing ring
Viewfinder mount base