JVC GY-HD200UB GY-HD200U Owner's Manual - Page 90
How to set the HEADER REC menu screen, Executing the HEADER REC Function
UPC - 046838035616
View all JVC GY-HD200UB manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
SHOOTING OPERATION HEADER REC Function When the REC/VTR trigger button is pressed while the STOP button is pressed, this function first records the color bar video and the test tone (1 kHz sine-wave) of the built-in signal generator at the beginning of the tape. Then it records the black video signal and the mute audio signal for the duration specified in advance. When the recording is completed, this device enters the RecordStandby mode. The time code value at the Record-Standby position becomes the time code specified in advance. (HEADER REC function) • Settings related to the HEADER REC function, such as whether the HEADER REC function should be enabled, the HEADER REC execution duration, and the time code value setting when the HEADER REC recording is completed, etc., are made on the HEADER REC menu screen. • The HEADER REC function is enabled when TCG SOURCE on the TC/UB/CLOCK menu screen is set to INTERNAL. • The HEADER REC function is executed under the following circumstances: CAM/VTR button: Set to CAM mode. In the Record-Standby or Stop mode Tape beginning HEADER REC (Example) 30 sec Record-Standby mode (Example) 30 sec Normal recording Color bar video signal Test tone (1 kHz) (Setting range: 0 to 99 sec) Time code, user's bits recording Black video signal Mute audio (No sound) (Setting range: 0 to 99 sec) Time code, user's bits recording Time code: The value specified on the HEADER REC menu screen- HEADER REC time. (Example) 23:59:00:00 User's bits: The value specified for the UB DATA item on the HEADER REC menu screen. Time code: The value specified on the HEADER REC menu screen. (Example) 00:00:00:00 User's bits: The value specified for the UB PRESET item on the TC/UB/ CLOCK menu screen. (only when set to REC RUN or FREE RUN mode) HEADER REC menu screen contents Item Function/Initial Setting START KEY Sets whether the HEADER REC operation should be executed when the REC/VTR trigger button is pressed while the STOP button is pressed. DISABLE : HEADER REC operation is not executed. STOP+REC : HEADER REC operation is executed. TC DATA Sets the time code value for the point when the Record-Standby mode is engaged following completion of HEADER REC. EXECUTE : Confirms the set time code. ZERO PRESET: Resets all time codes to zero "0". CANCEL : Clears the set time code. The frame mode is set depending on the setting in the DROP FRAME item on the TC/UB/CLOCK menu screen. * The time code value at the point when the Record-Standby mode is engaged may differ some frames from the value set for this item. UB DATA Sets the user's bits of the HEADER REC section. EXECUTE : Confirms the set user's bits. ZERO PRESET: Resets all user's bits data to zero "0". CANCEL : Clears the set user's bits. MEMO The user's bits for the normal recording section are set on the TC/UB/CLOCK menu screen. BARS TIME BLACK TIME PAGE BACK Sets the duration (seconds) in which the color bar signal and test tone (1 kHz) is recorded during HEADER REC. (1-sec steps) [Initial Setting: 0SEC - 30SEC - 99SEC] Sets the duration (seconds) in which the black signal is recorded during HEADER REC. (1-sec steps) [Initial Setting: 0SEC - 30SEC - 99SEC] The TC/UB/CLOCK menu screen returns when the SHUTTER dial is pressed. 60 How to set the HEADER REC menu screen 1. Display the HEADER REC menu screen. 1Select the TC/UB/CLOCK.. item on the TOP MENU screen. 2Select the HEADER REC item on the TC/UB/CLOCK menu screen. TC/UB/CLOCK menu screen specified duration only, the Record-Standby mode is engaged automatically. • During HEADER REC recording, "HEADER REC" is shown (blinking) on the LCD monitor and in the viewfinder. HEADER REC menu screen 2. Setting the HEADER REC menu screen. 1Select the menu item. Rotate the SHUTTER dial to align the cursor (K) with the item to be set, and then press the SHUTTER dial. • The setting area of the selected item starts blinking. 2Changing the setting value. Rotate the SHUTTER dial to change the setting, and then press the SHUTTER dial. Cursor Item Set value In the case of the TC DATA item and the UB DATA item, the blinking digit position moves when the SHUTTER dial is pressed. When the SHUTTER dial is rotated, the value of the blinking digit changes. After all the digits have been set and the SHUTTER dial is pressed, EXECUTE starts blinking. Press the SHUTTER dial once more to confirm the set value. 3. To terminate the setting, press the STATUS button. Executing the HEADER REC Function The START KEY item on the HEADER REC menu screen should be set to STOP+REC. 1. Load the cassette and engage the Record-Standby mode or the Stop mode. 2. While pressing the STOP button, press the REC/VTR trigger button. • The tape automatically rewinds to the beginning, and HEADER REC operation starts from the beginning of the tape. After HEADER REC recording is performed for the During HEADER REC • The menu screen is not displayed during HEADER REC recording. 3. After HEADER REC recording is completed and the Record-Standby mode is engaged, normal recording starts when you press the REC/VTR trigger button. • When the TC GENE. switch is set to either REC or REGEN, the time code value at the start of the HEADER REC menu screen. MEMO • To stop during HEADER REC operation, press the REC/ VTR trigger button or the STOP button. • The HEADER REC menu screen cannot be opened dur- ing HEADER REC recording. • HEADER REC operation is accepted even during load- ing of the cassette tape. • The test tone (1 kHz sine-wave) recorded in the color bar section will be recorded unrelated to the setting for the TEST TONE item on the AUDIO/MIC[1/2] menu screen. • The time code preset on the TC/UB/CLOCK menu screen becomes invalid when HEADER REC recording is performed. • The user's bits following completion of HEADER REC recording will be the user's bits value set on the TC/UB/ CLOCK menu screen. • The running of the time code following completion of HEADER REC recording will be in accordance with the setting of the TC GENE. switch. FREE RUN : Continuous running. REC RUN or REGEN: Runs only during REC. • Camera images are not output to the LCD monitor, view- finder or video output during REW mode when the HEADER REC operation begins. 61