Kenwood TS-590SG Operation Manual - Page 59

Quick Memory Scan

Page 59 highlights

GROUP SCAN 110 memory channels are divided into 11 groups so that you can select one or more groups to be scanned, depending on the situation. ■ Memory Group When you store frequency data in a memory channel, the memory channel belongs to one of 11 groups as shown below. MGROUP-0 MGROUP-1 MGROUP-2 MGROUP-3 MGROUP-4 MGROUP-5 MGROUP-6 MGROUP-7 MGROUP-8 MGROUP-9 MGROUP-P MGROUP-E Memory Channel Nos. 00 ~ 09 Memory Channel Nos. 10 ~ 19 Memory Channel Nos. 20 ~ 29 Memory Channel Nos. 30 ~ 39 Memory Channel Nos. 40 ~ 49 Memory Channel Nos. 50 ~ 59 Memory Channel Nos. 60 ~ 69 Memory Channel Nos. 70 ~ 79 Memory Channel Nos. 80 ~ 89 Memory Channel Nos. 90 ~ 99 Memory Channel Nos. P0 ~ P9 Memory Channel Nos. E0 ~ E9 ■ Scan Group Select You can select one or more groups to be scanned. First, select the groups to be scanned. 1 Press [M/V] to enter Memory Recall mode. • " " appears. 2 Press and hold [SCAN (SG.SEL)] to enter Scan Group Select mode. 3 As you turn the MULTI/CH control, the MGROUP number on the sub-display changes. • MGROUP-0 represents Memory channels 0 ~ 9, MGROUP-1 represents Memory channels 10 ~ 19 and so on up to MGROUP-9 which represents Memory channels 90 ~ 99 and MGROUP-P which represents Memory channels P0 ~ P9. 4 Press [M.IN] to select "on" to add the group to the Group Scan list. • If you do not want to scan the selected Group, press [SCAN (SG.SEL)] to select "oFF". 5 Press and hold [SCAN (SG.SEL)] or [CLR]. to exit the Scan Group Select mode. SCAN 11 ■ Performing Group Scan Group Scan starts with the smallest group number and repeats the sequence. For example, if you selected "on" for MGROUP-3, MGROUP-5, and MGROUP-7, the transceiver scans the channels in MGROUP-3 > MGROUP-5 > MGROUP-7 > MGROUP-3 and so on. 1 Select Time-Operated or Carrier-Operated mode via Menu No. 26. 2 Press [M/V] to enter Memory Recall mode. 3 Turn the SQL control to adjust the squelch threshold. 4 Press [SCAN (SG.SEL] to start Memory Group Scan. • Scan ascends up through the channel numbers. (The scan direction cannot be changed.) • To jump to a desired channel while scanning, turn the MULTI/CH control or press and hold Mic [UP]/ [DWN]. 5 To stop Scan, press [SCAN (SG.SEL)] or [CLR]. Note: ◆ If you have turned the SQL control clockwise, far beyond the squelch threshold, Scan may fail to stop at a channel in which a signal is present. If this happens, turn the SQL control slightly counterclockwise. ◆ When the current channel is within one of the groups that you selected, Scan starts with the current channel. ◆ When the current channel is outside all the groups that you selected, Scan starts with the group number that is larger than and closest to the group number of the current channel. ◆ Starting Memory Scan switches OFF the RIT and XIT functions. QUICK MEMORY SCAN 1 Press [Q-MR] to enter Quick Memory mode. 2 Press [SCAN (SG.SEL] to start Quick Memory Scan. • Scan starts from the current quick memory channel and ascends up through the channel numbers. (The scan direction cannot be changed.) 3 To stop Scan, press [SCAN (SG.SEL)] or [CLR]. 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

51
SCAN
11
GROUP SCAN
110 memory channels are divided into 11 groups
so that you can select one or more groups to be
scanned, depending on the situation.
Memory Group
When you store frequency data in a memory
channel, the memory channel belongs to one of 11
groups as shown below.
MGROUP-0
Memory Channel Nos. 00 ~ 09
MGROUP-1
Memory Channel Nos. 10 ~ 19
MGROUP-2
Memory Channel Nos. 20 ~ 29
MGROUP-3
Memory Channel Nos. 30 ~ 39
MGROUP-4
Memory Channel Nos. 40 ~ 49
MGROUP-5
Memory Channel Nos. 50 ~ 59
MGROUP-6
Memory Channel Nos. 60 ~ 69
MGROUP-7
Memory Channel Nos. 70 ~ 79
MGROUP-8
Memory Channel Nos. 80 ~ 89
MGROUP-9
Memory Channel Nos. 90 ~ 99
MGROUP-P
Memory Channel Nos. P0 ~ P9
MGROUP-E
Memory Channel Nos. E0 ~ E9
Scan Group Select
You can select one or more groups to be scanned.
First, select the groups to be scanned.
1
Press
[M/V]
to enter Memory Recall mode.
” appears.
2
Press and hold
[SCAN (SG.SEL)]
to enter Scan
Group Select mode.
3
As you turn the
MULTI/CH
control,
the
MGROUP number on the sub-display changes.
MGROUP–0 represents Memory channels
0 ~ 9, MGROUP–1 represents Memory
channels 10 ~ 19 and so on up to
MGROUP–9 which represents Memory
channels 90 ~ 99 and MGROUP-P which
represents Memory channels P0 ~ P9.
4
Press
[M.IN]
to select “on” to add the group to
the Group Scan list.
If you do not want to scan the selected
Group, press
[SCAN (SG.SEL)]
to select
“oFF”.
5
Press and hold
[SCAN (SG.SEL)]
or
[CLR]
. to
exit the Scan Group Select mode.
Performing Group Scan
Group Scan starts with the smallest group number
and repeats the sequence.
For example, if you
selected “on” for MGROUP–3, MGROUP–5, and
MGROUP–7, the transceiver scans the channels
in MGROUP–3 > MGROUP–5 > MGROUP–7 >
MGROUP–3 and so on.
1
Select Time-Operated or Carrier-Operated
mode via Menu No. 26.
2
Press
[M/V]
to enter Memory Recall mode.
3
Turn the
SQL
control to adjust the squelch
threshold.
4
Press
[SCAN (SG.SEL]
to start Memory Group
Scan.
Scan ascends up through the channel
numbers. (The scan direction cannot be
changed.)
To jump to a desired channel while
scanning, turn the
MULTI/CH
control or
press and hold Mic
[UP]
/
[DWN]
.
5
To stop Scan, press
[SCAN (SG.SEL)]
or
[CLR]
.
Note:
If you have turned the
SQL
control clockwise, far beyond
the squelch threshold, Scan may fail to stop at a channel
in which a signal is present.
If this happens, turn the
SQL
control slightly counterclockwise.
When the current channel is within one of the groups
that you selected, Scan starts with the current channel.
When the current channel is outside all the groups that
you selected, Scan starts with the group number that
is larger than and closest to the group number of the
current channel.
Starting Memory Scan switches OFF the RIT and XIT
functions.
QUICK MEMORY SCAN
1
Press
[Q-MR]
to enter Quick Memory mode.
2
Press
[SCAN (SG.SEL]
to start Quick Memory
Scan.
Scan starts from the current quick memory
channel and ascends up through the channel
numbers. (The scan direction cannot be
changed.)
3
To stop Scan, press
[SCAN (SG.SEL)]
or
[CLR]
.