13 CONNECTING PERIPHERAL EQUIPMENT REMOTE CONNECTOR GND GND: Connecting to the metal shield. Pin No. Pin Name Function I/O 1 SPO Speaker output O 2 COM Common terminal I/O Standby; when grounded, the transceiver enters TX mode. 3 SS • During transmission, the audio input of ACC2 connector I terminal 11 (ANI) and the USB terminal are muted. 4 MKE When connected with the common terminal, the amplifier enters TX mode. I/O 5 BRK When connected with the common terminal, the amplifier enters RX mode. I/O 6 ALC ALC input from the amplifier (approx. -7 V). I 7 RL Approx. +12 V DC is output when in TX mode (10 mA max.). O EXT.AT CONNECTOR (for AT-300) Pin No. Pin Name Function I/O 1 GND Ground - 2 TT AT-300 control input/ output I/O 3 GND Ground - 4 NC No connection - 5 TS AT-300 control input/ output I/O 6 14S Power supply for EXT.AT Switched 13.8 V (4 A max.). O MIC CONNECTOR Pin No. Pin Name Function I/O 1 MIC MIC signal input I 2 SS MIC standby (PTT) control I 3 MD MIC Down control I 4 MU MIC UP control I 5 8A Switched 8 V (10 mA max.) O 6 NC No connection - 7 MSG MIC GND - 8 MCG GND - Note: ◆ The terminal pin numbers are arranged as seen on the front and rear panel. ◆ Do not use a cable exceeding 3 m (9.8 feet) with the following connectors: PHONES jack MIC connector COM connector EXT. SP jack ACC 2 connector KEY jack PADDLE jack DRV connector USB connector REMOTE connector 72