Kenwood TS-590SG Operation Manual - Page 84
Antenna Tuner, Compatible Transceiver Split Transfer
View all Kenwood TS-590SG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
13 CONNECTING PERIPHERAL EQUIPMENT TX/RX CONTROL To connect a linear amplifier, configure to enable the control signal state in Menu No. 59 (HF) and Menu No. 60 (50 MHz), and make the appropriate connections between the TX/RL control terminals of the TS-590SG and the linear amplifier. GND COM RL CONT MKE REMOTE connector (front view) ALC GND ANTENNA TUNER Use the ANT 1 and AT connectors to connect an AT-300 external antenna tuner. If you connect the external antenna tuner to the ANT 2 connector, it will not function. Note: ◆ The AT-300 cannot be used for 50 MHz operation. ◆ The AT-300 has been discontinued and is no longer available. TS-590SG ANT 1 connector AT-300 COMPATIBLE TRANSCEIVER (SPLIT TRANSFER) When transferring data to or from another TS-990S, TS-890S, TS-590SG, TS-590S, TS-480HX/SAT, TS-2000/X, TS-570S/D, or TS-870S, directly connect the 2 transceivers using the COM connectors. TS-590SG Compatible transceiver (f) RS-232C cross cable (f) DB-9 connector wiring (Cross-wired) 76