Kenwood TS-590SG Operation Manual - Page 63

Display, Panel Key Double Function, Response Time, Linear Amplifier Control

Page 63 highlights

Beep Type Morse "AR" Meaning The current message memory is full. DISPLAY BRIGHTNESS The brightness of the LCD display can be selected from OFF, and 1 to 6 . 1 Press [MENU], then press [Q-M.IN]/ [Q-MR] or turn the MULTI/CH control to access Menu No. 02. 2 Press [M.IN]/ [SCAN (SG.SEL)] to select "oFF", "1", "2", "3", "4", "5", or "6". 3 Press [MENU] to exit Menu mode. BACKLIGHT COLOR You can manually change the display illumination to suit the lighting conditions where you are operating. 1 Press [MENU], then press [Q-M.IN]/ [Q-MR] or turn the MULTI/CH control to select Menu No. 03. 2 Press [M.IN]/ [SCAN (SG.SEL)] to select "1" (amber), "2" to "9" (mixed colors), or "10" (green). 3 Press [MENU] to exit Menu mode. PANEL KEY DOUBLE FUNCTION RESPONSE TIME You can set the response time of double function panel keys to normal or fast. The default setting is normal. 1 Press [MENU], then press [Q-M.IN]/ [Q-MR] or turn the MULTI/CH control to select Menu No. 04. 2 Press [M.IN]/ [SCAN (SG.SEL)] to select "1" (0.2 second), "2" (0.5 second) or "3" (1 second). 3 Press [MENU] to exit Menu mode. OPERATOR CONVENIENCES 12 LINEAR AMPLIFIER CONTROL To connect the linear amplifier to the REMOTE connector on the rear panel and to operate in the HF or 50 MHz band, you can configure to enable or disable the control signal state and the transmission delay time. 1 Press [MENU], then press [Q-M.IN]/ [Q-MR] or turn the MULTI/CH control to select Menu No. 59 (HF) or 60 (50 MHz). 2 Press [M.IN]/ [SCAN (SG.SEL)] to select "oFF", "1", "2", "3", "4", or "5". 3 Press [MENU] to exit Menu mode. Setting RL Terminal Operation *1 Relay Operation *2 Delay *3 oFF - 1 While TX: 12 V 2 While TX: 12 V 3 While TX: 12 V 4 While TX: Short to GND 5 While TX: Short to GND - OFF ON ON OFF OFF - OFF OFF ON OFF ON *1: Semiconductor Switch output. When transmitting, set it to either perform a voltage output or a short circuit to GND. It is possible to perform the operation quietly, without activating the relay. As a guide, a current of 10 mA or lower can be controlled. In order to protect the internal circuit, a resistance of 100  is inserted in series and the voltage is shifted according to the flow of the electric current. For example, when an electric current of 10 mA flows, the voltage decreases (when set as 1/2/3) or increases (when set as 4/5) by 1 V. Use a range that does not cause any problems with your equipment. *2: Mechanical Relay Operation. You can switch the signal of the high voltage like a vacuum tube linear amplifier. It is possible to control the terminal voltage of TL-922 (approximately -140 V). *3: This function extends the time from when the transmission starts to when the signal is sent (normally approximately 10 ms), and from when the transmission ends to when audio output starts to be received (normally approximately 25 ms). When using a linear amplifier or other device that takes a relatively long time to switch between receiving and transmitting, or transmitting and receiving, such as the TL-922, you can prevent problems such as noise or malfunctions. Delay Time: CW/FSK: approx. 25 ms SSB/AM/FM: approx. 45 ms 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

55
OPERATOR CONVENIENCES
12
Beep Type
Meaning
Morse “AR”
The current message memory
is full.
DISPLAY
BRIGHTNESS
The brightness of the LCD display can be selected
from OFF, and 1 to 6 .
1
Press
[MENU]
, then press
[Q-M.IN]
/
[Q-MR]
or
turn the
MULTI/CH
control to access Menu No. 02.
2
Press
[M.IN]
/
[SCAN (SG.SEL)]
to select “oFF”,
“1”, “2”, “3”, “4”, “5”, or “6”.
3
Press
[MENU]
to exit Menu mode.
BACKLIGHT COLOR
You can manually change the display illumination to
suit the lighting conditions where you are operating.
1
Press
[MENU]
, then press
[Q-M.IN]
/
[Q-MR]
or
turn the
MULTI/CH
control to select Menu No. 03.
2
Press
[M.IN]
/
[SCAN (SG.SEL)]
to select “1”
(amber), “2” to “9” (mixed colors), or “10” (green).
3
Press
[MENU]
to exit Menu mode.
PANEL KEY DOUBLE FUNCTION
RESPONSE TIME
You can set the response time of double function
panel keys to normal or fast.
The default setting is
normal.
1
Press
[MENU]
, then press
[Q-M.IN]
/
[Q-MR]
or
turn the
MULTI/CH
control to select Menu No. 04.
2
Press
[M.IN]
/
[SCAN (SG.SEL)]
to select “1” (0.2
second), “2” (0.5 second) or “3” (1 second).
3
Press
[MENU]
to exit Menu mode.
LINEAR AMPLIFIER CONTROL
To connect the linear amplifier to the REMOTE
connector on the rear panel and to operate in the
HF or 50 MHz band, you can configure to enable or
disable the control signal state and the transmission
delay time.
1
Press
[MENU]
, then press
[Q-M.IN]
/
[Q-MR]
or
turn the
MULTI/CH
control to select Menu No. 59
(HF) or 60 (50 MHz).
2
Press
[M.IN]
/
[SCAN (SG.SEL)]
to select “oFF”,
“1”, “2”, “3”, “4”, or “5”.
3
Press
[MENU]
to exit Menu mode.
Setting
RL Terminal
Operation
*
1
Relay
Operation
*
2
Delay
*
3
oFF
1
While TX: 12 V
OFF
OFF
2
While TX: 12 V
ON
OFF
3
While TX: 12 V
ON
ON
4
While TX:
Short to GND
OFF
OFF
5
While TX:
Short to GND
OFF
ON
*
1:
Semiconductor Switch output.
When transmitting,
set it to either perform a voltage output or a
short circuit to GND.
It is possible to perform
the operation quietly, without activating the relay.
As a guide, a current of 10 mA or lower can be
controlled. In order to protect the internal circuit,
a resistance of 100
is inserted in series and
the voltage is shifted according to the flow of the
electric current. For example, when an electric
current of 10 mA flows, the voltage decreases
(when set as 1/2/3) or increases (when set as
4/5) by 1 V. Use a range that does not cause any
problems with your equipment.
*
2:
Mechanical Relay Operation.
You can switch the
signal of the high voltage like a vacuum tube linear
amplifier.
It is possible to control the terminal
voltage of TL-922 (approximately -140 V).
*
3:
This function extends the time from when the
transmission starts to when the signal is sent
(normally approximately 10 ms), and from when
the transmission ends to when audio output starts
to be received (normally approximately 25 ms).
When using a linear amplifier or other device that
takes a relatively long time to switch between
receiving and transmitting, or transmitting and
receiving, such as the TL-922, you can prevent
problems such as noise or malfunctions.
Delay Time:
CW/FSK: approx. 25 ms
SSB/AM/FM: approx. 45 ms