Kodak S1220 User Guide - Page 60
Adjusting the pre-separation roller tension
UPC - 041778466193
View all Kodak S1220 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
6. Replace the core assembly in the feed module. You may need to slide the shaft to the right or left so the core fits properly within the feed module housing. Adjusting the preseparation roller tension 7. Repeat the replacement procedure outlined above for the other core assembly. 8. Reinstall the feed module. 9. Reinstall the feed module cover by aligning the tabs in the slots and pushing the feed module cover down until it snaps into place. If you are experiencing multi-feeds or document jams, it may be necessary to adjust the pre-separation roller tension. 1. Remove the separation module from the scanner by following the steps described previously in "Replacing the separation module and tires". 2. Locate the spring on the separation module. 3. Lift the spring from the holder and move it to the left or right as desired to adjust the tension. A-61601 February 2010 5-13