Lantronix MatchPort b/g MatchPort b/g - User Guide - Page 17

Number of Ports

Page 17 highlights

3: Using DeviceInstaller Gateway Non-configurable field. Displays the MatchPort's current gateway. To change the gateway, see 4: Configuration Using Web-Manager or 5: Configuration via Serial Mode or Telnet Port. Number of COB Non-configurable field. Displays the number of COB partitions partitions supported supported (19). Number of Ports Non-configurable field. Displays the number of ports on the MatchPort. TCP Keepalive Non-configurable field. Displays 1-65s, the MatchPort's TCP keepalive range. The default setting is 45. Telnet Supported Non-configurable field. Displays True, indicating that the user can access the MatchPort by means of a Telnet session. Telnet Port Non-configurable field. Displays the MatchPort's port for Telnet sessions. Web Port Non-configurable field. Displays the MatchPort's port for WebManager configuration. Maximum Baud Rate Supported Non-configurable field. Displays the MatchPort's maximum baud rate. Note: The MatchPort may not currently be running at this rate. Firmware Upgradeable Non-configurable field. Displays True, indicating the MatchPort's firmware is upgradeable as newer versions become available. Supports Configurable Pins Non-configurable field. Displays True, indicating configurable pins are available on the MatchPort. Supports Email Triggers Non-configurable field. Displays True, indicating email triggers are available on the MatchPort. Supports AES Data Non-configurable field. Displays True if the MatchPort unit supports Stream AES encryption. Supports 485 Non-configurable field. Displays True, indicating the MatchPort supports the RS-485 protocol. Supports 921K Baud Rate Non-configurable field. Displays True. Supports Wired Ethernet* Non-configurable field. Displays True. *MatchPort b/g only Supports HTTP Server Supports HTTP Setup Supports 230K Baud Rate Supports GPIO Non-configurable field. Displays True. Non-configurable field. Displays True. Non-configurable field. Displays True. Non-configurable field. Displays True, indicating MatchPort supports communication via General Purpose Input Output (GPIO). MatchPort User Guide 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

3: Using DeviceInstaller
Gateway
Non-configurable field. Displays the MatchPort’s current gateway. To
change the gateway, see
4: Configuration Using Web-Manager
or
5:
Configuration via Serial Mode or Telnet Port
.
Number of COB
partitions supported
Non-configurable field. Displays the number of COB partitions
supported (19).
Number of Ports
Non-configurable field. Displays the number of ports on the
MatchPort.
TCP Keepalive
Non-configurable field. Displays
1-65s
, the MatchPort’s TCP
keepalive range. The default setting is
45
.
Telnet Supported
Non-configurable field. Displays
True
, indicating that the user can
access the MatchPort by means of a Telnet session.
Telnet Port
Non-configurable field. Displays the MatchPort’s port for Telnet
sessions.
Web Port
Non-configurable field. Displays the MatchPort’s port for Web-
Manager configuration.
Maximum Baud
Rate Supported
Non-configurable field. Displays the MatchPort’s maximum baud rate.
Note:
The MatchPort may not currently be running at this rate.
Firmware
Upgradeable
Non-configurable field. Displays
True
, indicating the MatchPort’s
firmware is upgradeable as newer versions become available.
Supports
Configurable Pins
Non-configurable field. Displays
True
, indicating configurable pins are
available on the MatchPort.
Supports Email
Triggers
Non-configurable field. Displays
True
, indicating email triggers are
available on the MatchPort.
Supports AES Data
Stream
Non-configurable field. Displays
True
if the MatchPort unit supports
AES encryption.
Supports 485
Non-configurable field. Displays
True,
indicating the MatchPort
supports the RS-485 protocol.
Supports 921K
Baud Rate
Non-configurable field. Displays
True
.
Supports Wired
Ethernet*
Non-configurable field. Displays
True
.
*MatchPort b/g only
Supports HTTP
Server
Non-configurable field. Displays
True.
Supports HTTP
Setup
Non-configurable field. Displays
True.
Supports 230K
Baud Rate
Non-configurable field. Displays
True
.
Supports GPIO
Non-configurable field. Displays
True
, indicating MatchPort supports
communication via General Purpose Input Output (GPIO).
MatchPort User Guide