Lantronix MatchPort b/g MatchPort b/g - User Guide - Page 60

DisConnTime (Inactivity Timeout), SendChar 1 and SendChar 2, Telnet Terminal Type

Page 60 highlights

5: Configuration via Serial Mode or Telnet Port Note: A transmission might occur if status information needs to be exchanged or an acknowledgment needs to be sent. DisConnTime (Inactivity Timeout) Use this parameter to set an inactivity timeout. The unit drops the connection if there is no activity on the serial line before the set time expires. Enter time in the format mm:ss, where m is the number of minutes and s is the number of seconds. DisConnTime (0: 0) ?: To disable the inactivity timeout, enter 00:00. Range is 0 (disabled) to 5999 seconds (99 minutes, 59 seconds). The default is 0. SendChar 1 and SendChar 2 Enter up to two characters in hexadecimal representation. SendChar 1 ( 0) ? _ SendChar 2 ( 0) ? _ If the unit receives a character on the serial line that matches one of these characters, it sends the character immediately, along with any awaiting characters, to the TCP connection. This action minimizes the response time for specific protocol characters on the serial line (for example, ETX, EOT). Setting the first SendChar to 00 disables the recognition of the characters. Alternatively, the unit can interpret two characters as a sequence (see Pack Control). Telnet Terminal Type This parameter displays only if the terminal type option is enabled in Disconnect Mode. If this option is enabled, use the terminal name for the Telnet terminal type. Enter only one name. If the terminal type option is enabled, the unit also reacts to the EOR (end of record) and binary options, which can be used for applications such as terminal emulation to UNIX hosts. Channel (Port) Password This parameter appears only if the channel (port) password option is enabled in Disconnect Mode. If the option is enabled, set a password on the serial port. Email Configuration The unit sends an email to multiple recipients when a specific trigger event occurs. There are three separate triggers, based on any combination of the configurable pins (PIO) when selected as user I/O functions. Optionally, use a two-byte serial string to initiate a trigger. To configure email configuration settings, select option 3 Email from the Change Setup menu. MatchPort User Guide 60

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

5: Configuration via Serial Mode or Telnet Port
Note:
A transmission might occur if status information needs to be
exchanged or an acknowledgment needs to be sent.
DisConnTime (Inactivity Timeout)
Use this parameter to set an inactivity timeout. The unit drops the connection if there
is no activity on the serial line before the set time expires. Enter time in the format
mm:ss
, where
m
is the number of minutes and
s
is the number of seconds.
DisConnTime (0: 0) ?:
To disable the inactivity timeout, enter
00:00
. Range is 0 (disabled) to 5999 seconds
(99 minutes, 59 seconds). The default is
0
.
SendChar 1 and SendChar 2
Enter up to two characters in hexadecimal representation.
SendChar 1 ( 0) ? _
SendChar 2 ( 0) ? _
If the unit receives a character on the serial line that matches one of these
characters, it sends the character immediately, along with any awaiting characters, to
the TCP connection. This action minimizes the response time for specific protocol
characters on the serial line (for example, ETX, EOT). Setting the first SendChar to
00
disables the recognition of the characters. Alternatively, the unit can interpret two
characters as a sequence (see
Pack Control
).
Telnet Terminal Type
This parameter displays only if the terminal type option is enabled in Disconnect
Mode. If this option is enabled, use the terminal name for the Telnet terminal type.
Enter only one name.
If the terminal type option is enabled, the unit also reacts to the EOR (end of record)
and binary options, which can be used for applications such as terminal emulation to
UNIX hosts.
Channel (Port) Password
This parameter appears only if the channel (port) password option is enabled in
Disconnect Mode. If the option is enabled, set a password on the serial port.
Email Configuration
The unit sends an email to multiple recipients when a specific trigger event occurs.
There are three separate triggers, based on any combination of the configurable pins
(PIO) when selected as user I/O functions. Optionally, use a two-byte serial string to
initiate a trigger. To configure email configuration settings, select option
3 Email
from
the Change Setup menu.