Netgear FSM7328PS FSM7328PS Hardware manual - Page 10

FSM7328S Front Panel and LEDs, Table 2-1. LED Descriptions for FSM7328S

Page 10 highlights

Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide FSM7328S Front Panel and LEDs The following figure shows the front panel of the FSM7328S. The front panel contains LEDs, RJ-45 jacks, SFP module bays, stacking ports, and a console port. LEDs Figure 2-1 RJ-45 jacks SFP module bays Stacking ports Console port The following table shows the LEDs on the front panel of the switch. Table 2-1. LED Descriptions for FSM7328S LED Description Master Power Fan 10/100M ports One LED per port Green: This switch is the master of the stack. Off: The switch is not the master of the stack. Solid green: Power is supplied, and the switch is operating normally. Blinking green: Runtime code load in progress. Solid yellow: Power-On Self-Test (POST) in progress. Blinking yellow: POST failure or CPU failure. Off: Power is disconnected. Solid red: Fan has failed. Off: Fan is present and operating normally. Link/ACT/SPD LED • Off: No 10/100 Mbps link is established on the port. • Solid green: A valid 100 Mbps link is established on the port. • Blinking green: The port is sending or receiving packets at 100 Mbps. • Solid yellow: A valid 10 Mbps link is established on the port. • Blinking yellow: The port is sending or receiving packets at 10 Mbps. 2-2 Introduction v1.0, May 2007

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide
2-2
Introduction
v1.0, May 2007
FSM7328S Front Panel and LEDs
The following figure shows the front panel of the FSM7328S. The front panel
contains LEDs, RJ-45 jacks, SFP module bays, stacking ports, and a console port.
The following table shows the LEDs on the front panel of the switch.
Figure 2-1
Table 2-1. LED Descriptions for FSM7328S
LED
Description
Master
Green:
This switch is the master of the stack.
Off:
The switch is not the master of the stack.
Power
Solid green:
Power is supplied, and the switch is operating normally.
Blinking green:
Runtime code load in progress.
Solid yellow:
Power-On Self-Test (POST) in progress.
Blinking yellow:
POST failure or CPU failure.
Off:
Power is disconnected.
Fan
Solid red:
Fan has failed.
Off:
Fan is present and operating normally.
10/100M ports
One LED per port
Link/ACT/SPD LED
Off:
No 10/100 Mbps link is established on the port.
Solid green:
A valid 100 Mbps link is established on the port.
Blinking green:
The port is sending or receiving packets at
100 Mbps.
Solid yellow:
A valid 10 Mbps link is established on the port.
Blinking yellow:
The port is sending or receiving packets at 10
Mbps.
SFP module bays
Console port
Stacking ports
RJ-45 jacks
LEDs