Netgear FSM7328PS FSM7328PS Hardware manual - Page 12

FSM7328PS Front Panel and LEDs, Table 2-2. LED Descriptions for FSM7328PS - software

Page 12 highlights

Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide FSM7328PS Front Panel and LEDs The following figure shows the front panel of the FSM7328PS. The front panel contains LEDs, RJ-45 jacks, SFP module bays, and stacking ports. ID PoE 1 L/A 3 5 7 9 11 13 15 17 19 21 23 Stack Master Link/ACT BPS Fan PWR MaxPoE RST PoE: Green=PoE Active Yellow=Poe Fault 2 4 L/A: Green=link at 100M Yellow+Link at 10M Blink=Activity 6 8 10 12 14 16 18 20 22 24 25 26 27 28 LEDs Figure 2-3 RJ-45 jacks SFP module bays Stacking ports The following table shows the LEDs on the front panel of the switch. Table 2-2. LED Descriptions for FSM7328PS LED ID Master Power Fan MAX PoE RPS (redundant power supply) Description This is the stack member ID (1-8) that the software assigns to the switch. Green: This switch is the master of the stack. Off: The switch is not the master of the stack. Solid green: Power is supplied, and the switch is operating normally. Blinking green: Runtime code load in progress. Solid yellow: Power-On Self-Test (POST) in progress. Blinking yellow: POST failure or CPU failure. Off: Power is disconnected. Solid red: Fan has failed. Off: Fan is present and operating normally. Solid yellow: Less than 15.4 W of PoE power is available. Blinking yellow: The MAX PoE LED was active in the previous two minutes. Off: There is at least 7 W of PoE power available for another device. Solid green: RPS bank supply PoE power. Off: RPS bank is disconnected. 2-4 Introduction v1.0, May 2007

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

Managed Stackable Layer 3 Fast Ethernet Switches Hardware Installation Guide
2-4
Introduction
v1.0, May 2007
FSM7328PS Front Panel and LEDs
The following figure shows the front panel of the FSM7328PS. The front panel
contains LEDs, RJ-45 jacks, SFP module bays, and stacking ports.
The following table shows the LEDs on the front panel of the switch.
Figure 2-3
Table 2-2. LED Descriptions for FSM7328PS
LED
Description
ID
This is the stack member ID (1–8) that the software assigns to the
switch.
Master
Green:
This switch is the master of the stack.
Off:
The switch is not the master of the stack.
Power
Solid green:
Power is supplied, and the switch is operating normally.
Blinking green:
Runtime code load in progress.
Solid yellow:
Power-On Self-Test (POST) in progress.
Blinking yellow:
POST failure or CPU failure.
Off:
Power is disconnected.
Fan
Solid red:
Fan has failed.
Off:
Fan is present and operating normally.
MAX PoE
Solid yellow:
Less than 15.4 W of PoE power is available.
Blinking yellow:
The MAX PoE LED was active in the previous two
minutes.
Off:
There is at least 7 W of PoE power available for another device.
RPS (redundant
power supply)
Solid green:
RPS bank supply PoE power.
Off:
RPS bank is disconnected.
1
3
5
7
9
11
2
4
6
8
10
12
PoE
L/A
13
15
17
19
21
23
14
16
18
20
22
24
Master
25
26
27
28
BPS
Fan
PWR
MaxPoE
RST
ID
Green=PoE Active
Green=link at 100M
PoE:
L/A:
Yellow=Poe Fault
Yellow+Link at 10M
Blink=Activity
Stack
Link/ACT
SFP module bays
Stacking ports
RJ-45 jacks
LEDs