If the MFP has recently been powered on, some fuser components
View all Oki 62435901 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
FUSER REPLACEMENT The fuser is located inside the printer just behind the toner cartridges. WARNING! If the MFP has recently been powered on, some fuser components will be very hot. Handle the fuser with extreme care, holding it only by its handle, which will only be mildly warm to the touch. A warning label clearly indicates the area. Switch off the MFP and allow the fuser to cool for about 10 minutes before opening the cover. Refer to "Switching off" on page 18 for details. 1. Gently raise the scanner. 2. Press the cover release (a) and open the top cover (b) fully. b a 3. Identify the fuser handle (a) on the top of the fuser unit. a b b 4. Pull the two fuser retaining levers (b) towards the front of the printer so that they are fully upright. 5. Holding the fuser by its handle (a), lift the fuser straight up and out of the printer. If the fuser is still warm, place it on a flat surface which will not be damaged by heat. 6. Remove the new fuser from its packaging and remove the transit material. Maintenance > 105