Panasonic WJRT416V WJRT416V User Guide - Page 41
Rack mounting
View all Panasonic WJRT416V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
Rack mounting Use an EIA-standard 19" rack (depth: 550 mm or more). Note: It is necessary to procure four optional rack mount screws (W2-MSS/5008 or M5 x12). z Remove the five rubber feet from the bottom of the recorder using a flathead screwdriver. x Place the provided rack mounting brackets on both sides of the recorder and tighten with the eight provided screws. Remove the rubber feet. Rack mount bracket fixing screw (provided) c Install the recorder with the rack mounting brackets in the rack by using four rack mounting screws. Rack mount bracket (provided) Rack mounting screw: M5 x12 (locally procured) Important: • Keep the temperature in the rack below +45 °C {113 °F}. • Install the recorder in the rack as low as possible, and make a space of 1 unit (44 mm, 1.73") between the recorder and the other mounted appliances. • Do not block the front side of the rack such as by attaching a door panel, etc. • It is recommended to install cooling fans or equivalent equipment to keep the temperature in the rack below +30 °C {86 °F}. 41