Panasonic WVNW474S WVNW474S User Guide - Page 12
Connections, Power Connection
View all Panasonic WVNW474S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
■ Connections Cautions: • This product should be installed and connected in conformity with NEC by qualified service personnel or system installers. • Do not use a transformer with a capacity of more than 20 V A. • Use a class 2 power supply. • To prevent fire or electric shock hazard, use a UL listed cable (VW-1, style 1007) for 24 V AC connections. • Be sure to connect the GND (grounding) lead of the camera and grounding terminal of the power supply. Network Adapter (supplied) To network Video output BNC BNC To Video IN (CAMERA IN) Power 24 V AC Control cable To peripherals Adapter (supplied) Brown (Live) Blue (Neutral) Green/Yellow (GND) Black (Live) White (Neutral) For optional heater ● Power Connection Use individual power sources for the camera and optional heater unit. • Wire colors & functions Wire color Function Brown 24 V AC Live Blue 24 V AC Neutral Green/Yellow GND Black White 24 V AC Live 24 V AC Neutral Note For camera 8.6 W For optional heater 12.1 W • Cable length and wire gauge The recommended cable length and thickness are shown in the table for reference. The voltage supplied to the power terminals of the camera should be between 19.5 V AC and 28 V AC. Copper wire size #24 #22 #20 #18 (AWG) (0.22mm2) (0.33mm2) (0.52mm2) (0.83mm2) Length (m) 20 of cable (approx.) (ft) 65 30 45 75 100 160 260 -12-