Ricoh MP161SPF General Settings Guide - Page 117
Parameter Setting, Switches and Bits
View all Ricoh MP161SPF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 117 highlights
Parameter Setting Parameter Setting Parameter Setting allow you to customize various settings to suit your needs. To change function settings, set the Parameter Switches. ❖ Switches and Bits Each parameter setting has a set of switches, and each of the switches consist of eight bits, whose values are "0" or "1". The right most bit is bit 0 and the left most is bit 7. You can adjust the settings to match your needs by switching the value of bits between "0" and "1". Switch 02: 0 0 1 1 1 0 1 1 ↓ ↓ ↓ ↓ ↓ ↓ ↓ ↓ 4 7 6 5 4 3 2 1 0 ❖ Parameter Settings List Parameter Settings are outlined below. Switch Bit 02 0 02 3 03 0 03 2 03 3 03 4 03 5 03 7 04 1 04 4 04 5 Item 0 Forwarding Mark Off TSI Print Off Automatic printing of the Memory Off Transmission Result Report Automatic Printing of the Memory Off Storage Report Whether or not to print the SEP Off Code RX Reserve Report automatically. Whether or not to print the SEP Off Code RX Result Report automatically. Automatic printing of the Immedi- Off ate Transmission Result Report Automatic printing of the Journal Off Whether or not to print the Commu- Off nication Failure Report and Transfer Result Report automatically. Indicates the parties Off Include sender's name on reports Off 04 7 05 0 Include a portion of the image on reports Receive Service Call (SC) Condition (Substitute Reception during service call) Off Possible (Substitute RX) 1 On On On On On On On On On On On On Not possible (Reception Off) 107