Samsung NA24T4230FS/AA Installation Guide - Page 22
Supplied parts, BURNER ORIFICE SIZES AND OUTPUT RATINGS
![]() |
View all Samsung NA24T4230FS/AA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Supplied parts The following parts make up the LP conversion kit: BURNER ORIFICE SIZES AND OUTPUT RATINGS (Natural Gas 5 in WCP) Burner Location BTU Rate Orifice size [mm] LR 12500 1.65 LF 5000 1.00 RR 10500 1.45 RF 5000 1.00 The orifices' positions are marked on the provided sheet. The spud in the pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion requires spud removal and reinstallation for LP use. BURNER ORIFICE SIZES AND OUTPUT RATINGS (LP Gas [Propane] 10 in WCP) Burner Location BTU Rate Orifice size [mm] LR 11500 1.04 LF 5000 0.67 RR 9000 0.89 RF 5000 0.67 NOTE 145 Orifice markings: 145 - Denotes 1.45 mm orifice size opening. Installation instructions English 22
![](/manual_guide/products/samsung-na24t4230fsaa-installation-guide-5cccac5/22.png)
Installation instructions
Supplied parts
The following parts make up the LP conversion kit:
The orifices’ positions are marked on the provided sheet. The spud in the
pressure regulator is factory-installed for Natural Gas (NG) use. LP conversion
requires spud removal and reinstallation for LP use.
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(LP Gas [Propane] 10 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
LR
11500
1.04
LF
5000
0.67
RR
9000
0.89
RF
5000
0.67
BURNER ORIFICE SIZES AND OUTPUT RATINGS
(Natural Gas 5 in WCP)
Burner Location
BTU Rate
Orifice size [mm]
LR
12500
1.65
LF
5000
1.00
RR
10500
1.45
RF
5000
1.00
NOTE
145
Orifice markings:
145
– Denotes
1.45
mm orifice size opening.
English
22