Samsung NA24T4230FS/AA Installation Guide - Page 6

Installation safety, of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA.54, latest

Page 6 highlights

Important safety information Important safety information Installation safety WARNING To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the following precautions. • Have your cooktop installed and properly grounded by a qualified installer, in accordance with the installation instructions. Any adjustment and service should be performed only by qualified gas cooktop installers or service technicians. • Do not attempt to service, modify, or replace your cooktop or any part of your cooktop unless it is specifically recommended in this manual. All other service should be referred to a qualified technician. • Always use new flexible connectors when installing a gas appliance. Do not use old flexible connectors. • Make sure the hold down brackets are properly installed on the cooktop. See the installation instructions for more information. • Remove all tape and packaging materials. • Remove all accessories from the cooktop. Grates and griddles are heavy. Use caution when handling them. • Make sure no parts came loose during shipping. • Make sure your cooktop is correctly installed and adjusted by a qualified service technician or installer for the type of gas (natural or LP) you will use. For your cooktop to utilize LP gas, the installer must replace the 4 cooktop burner orifices with the provided LP orifice set, and reverse the regulator value. These adjustments must be made by a qualified service technician in accordance with the manufacturer's instructions and all codes and requirements of the authority having jurisdiction. The qualified agency performing this work assumes the gas conversion responsibility. • Installation of this cooktop must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA.54, latest edition. In Canada, the Natural Gas and Propane Installation Code, CSA B149.1. • A statement of the gas supply pressure for checking the regulator setting. [The pressure stated shall be at least 1 in wc (249 Pa) above the manufacturer's specified manifold pressure.] • Not obstructing the flow of combustion and ventilation air. • Top burner flame size sahll be adjusted so it does not extend beyond the edge of the cooking utensil. This instruction is based on safety considerations. 6 English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

6 English
Important safety information
Important safety information
• Make sure
your cooktop is correctly installed and adjusted by a qualified
service
technician or installer for the type of gas (natural or LP) you will use. For
your
cooktop to utilize LP gas, the installer must r
eplace the
4
cooktop burner orifices
with the provided LP orifice set, and reverse the
regulator value.
These
adjustments must be made by a qualified service technician in accordance with
the manufacturer’s instructions and all codes and requirements of the authority
having jurisdiction. The qualified agency performing this work assumes the gas
conversion responsibility.
Installation of this cooktop must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA.54, latest
edition. In Canada, the Natural Gas and Propane Installation Code, CSA B149.1.
A statement of the gas supply pressure for checking the regulator setting. [The
pressure stated shall be at least 1 in wc (249 Pa) above the manufacturer’s
specified manifold pressure.]
Not obstructing the flow of combustion and ventilation air.
Top burner flame size sahll be adjusted so it does not extend beyond the edge
of the cooking utensil. This instruction is based on safety considerations.
Installation safety
WARNING
To reduce the risk of fire, electric shock, personal injuries, and/or death, obey the
following precautions.
Have your cooktop installed and properly grounded by a
qualified installer
, in
accordance with the installation instructions. Any adjustment and service should
be performed only by qualified gas cooktop installers or service technicians.
• Do not attempt
to service, modify, or replace your cooktop or any part of your
cooktop unless it is specifically recommended in this manual. All other service
should be referred to a qualified technician.
Always use new flexible connectors when installing a gas appliance.
Do not use
old flexible connectors.
• Make sure
the hold down brackets are properly installed on the cooktop. See the
installation instructions for more information.
• Remove
all tape and packaging materials.
• Remove
all accessories from the cooktop. Grates and griddles are heavy. Use
caution when handling them.
• Make sure
no parts came loose during shipping.