Event Action Group
View all Samsung SRN-3250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
For Output Group, Output Source Duration is available to add and modify. Beep and Relay actions duration can be set from '1second' to 'always' (to make actions keep operating once an event occurs). To delete a group, select a group in a group list, and then click . Event Action Group Event Action Group links Event Input Group and Event Output Group into one functional unit, so that when an Event included in the Event Input Group occurs, all the responses included in the Event Output Group are included. Click under Event Action Group list, and you'll be directed to the screen shown below. This screen also appears when selecting a group and then clicking , or simply double clicking on a group. First, enter a new group name in Group Name. Then select Event Input and Output Groups in the Input Group and Output Group list. Events registered for the selected Input and Output Groups are at the bottom of the screen. Click to create the group. closes the Group Settings window without creating the group. To delete a group, select a group in the Group list, and then click . 48