PDG-DWL100 Expand Serial Command Functional Specifications 9.5.5 CR_SETPCADJ Command Command "CR_SETPCADJ" [CR] Details Get value of Signal name. Acceptable "000_%1" [CR] This command is available only Input is PC-Analog. Get value of Signal name. Correspondence %1 "640x480 VGA1 is input. "1024x768 XGA1 is input "1600x1200 UXGA1 is input Please tell us your spec about value of signal name. Unacceptable "?" [CR] --------- When unknown command is received 33 / 47
PDG-DWL100
Expand Serial Command Functional Specifications
33 / 47
9.5.5
CR_SETPCADJ Command
Command
“CR_SETPCADJ” [CR]
Details
Get value of Signal name.
Correspondence
Acceptable
“000_%1” [CR]
%1
This command is available only Input is PC-Analog.
Get value of Signal name.
“640x480”-----------------VGA1 is input.
“1024x768”----------------XGA1 is input
“1600x1200”--------------UXGA1 is input
Please tell us your spec about value of signal name.
Unacceptable
“?” [CR] --------- When unknown command is received