Sanyo PDG-DWL100 RS232C Expand - Page 7

CF_IMAGE, Select Image Mode, CF_INPUT, Select Input, CF_SCREEN, Select Screen Size, CF_SYSTEM,

Page 7 highlights

PDG-DWL100 Expand Serial Command Functional Specifications 3 Notes for communication 3.1 Expand Serial Command is defined as a single command per line that starts with "C" and ends with carriage return (0x0D). 3.2 When a projector receives carriage return (0x0D), it starts decoding. 3.3 There are two types of commands; the Functional Execution Command and the Status Read Command. Example of Functional Execution Command:"CF_BRIGHT_032" [CR] Example of Status Read Command: "CR_BRIGHT" [CR] Note) "_" indicates a space 3.4 It clears the information of buffer in the conditions bellow: When the projector receives LF (0x0A) or EOF (0x1A). When it takes more than one second to receive a single command. (Until receiving the carriage return after the reception of the first data.) 3.5 The projector processes commands and returns responses within a few ms to 8000 ms after the reception of the command. When several commands are issued in succession, do not send another command unless the response to the previous command has been returned; need to confirm that the processing of the current command has been completed and returned the response before sending another command. Command PC → Projector Projector → PC "CF_BRIGHT_032" [CR] "000" [CR] Command processing Response (A few ms - 8000 ms) Note) When the computer sends another command before the previous response has been returned, the projector may not operate properly. Note) When the current command processing has not been completed, another command process cannot be accepted by the projector. 3.5.1 Normally it is less than 1000ms for the completion of receiving a command and returning the response, but it takes more than 1000ms for some Functional Execution Commands (CF commands) as listed below: Command CF_IMAGE CF_INPUT CF_SCREEN CF_SYSTEM CF_IMAGEADJ Item Select Image Mode Select Input Select Screen Size Select System Reset/Store for Image Adjustment It takes about 8 seconds for the internal initialization after plugging in AC power. During this time commands cannot be processed. Do not issue any command. 7 / 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

PDG-DWL100
Expand Serial Command Functional Specifications
7 / 47
3
Notes for communication
3.1
Expand Serial Command is defined as a single command per line that starts with “C” and ends with
carriage return (0x0D).
3.2
When a projector receives carriage return (0x0D), it starts decoding.
3.3
There are two types of commands; the Functional Execution Command and the Status Read
Command.
Example of Functional Execution Command:”CF_BRIGHT_032” [CR]
Example of Status Read Command: “CR_BRIGHT” [CR]
Note) “_” indicates a space
3.4
It clears the information of buffer in the conditions bellow:
When the projector receives LF (0x0A) or EOF (0x1A).
When it takes more than one second to receive a single command.
(Until receiving the carriage return after the reception of the first data.)
3.5
The projector processes commands and returns responses within a few ms to 8000 ms after the
reception of the command.
When several commands are issued in succession, do not send another command unless the
response to the previous command has been returned; need to confirm that the processing of the
current command has been completed and returned the response before sending another
command.
Command
PC
Projector
“CF_BRIGHT_032”
[CR]
Projector
PC
“000”
[
CR]
Command processing
Response
(A few ms – 8000 ms)
Note)
When the computer sends another command before the previous response has been
returned, the projector may not operate properly.
Note)
When the current command processing has not been completed, another command
process cannot be accepted by the projector.
3.5.1
Normally it is less than 1000ms for the completion of receiving a command and returning the
response, but it takes more than 1000ms for some Functional Execution Commands (CF
commands) as listed below:
Command
Item
CF_IMAGE
Select Image Mode
CF_INPUT
Select Input
CF_SCREEN
Select Screen Size
CF_SYSTEM
Select System
CF_IMAGEADJ
Reset/Store for Image Adjustment
It takes about 8 seconds for the internal initialization after plugging in AC power.
During this time commands cannot be processed. Do not issue any command.