Sanyo PDG-DWL100 RS232C Expand - Page 46

CR_TEMPWARN Command, 12.6 CR_TEMPFAIL Command

Page 46 highlights

PDG-DWL100 Expand Serial Command Functional Specifications 9.12.5 CR_TEMPWARN Command Command "CR_TEMPWARN" [CR] Details Get the information about the temperature inside the projector (1) close to an abnormal status 2) in an abnormal status 3) temperature level is normal 4)abnormal status is not detected). Possible to get data from plural sensor s at once. Acceptable "000_%1" [CR] "*_*" Sensor 1 data comes first, and then one space, after that sensor 2 data is followed. Each data is as below: "W"--- in or close to the abnormal temp. (Warning Temp.) Correspondence %1 "S"--- in the safe level of temperature (Safe Temp.). "N"--- the given sensor does not detect abnormal temp. e.g. "S_W" [CR] indicates that the temperature detected at Sensor 1 is in the safe level while Sensor 2 in the abnormal temperature. Unacceptable "?" [CR] 9.12.6 CR_TEMPFAIL Command Command "CR_TEMPFAIL" [CR] Details Get the temperature inside the projector when the abnormal status occurs. Possible to get the data from plural sensors at once. Acceptable "000_%1" [CR] e.g. "_31.5F"[CR] _ indicates a space. When the temperature goes under 0, the first character become "-", such as "-05.5F". With more than one temperature sensors installed, projector returns the data of each sensor in order. e.g. "_31.5F_35.2S" [CR] The first data indicates sensor 1, then sensor 2 data follows after single space. Last character in each data indicates the status of temperature; Correspondence %1 In the abnormal temperature F" In the safe level of temperature S" Neither in or close to the abnormal temp. ------- "N" The second example above indicates that the temperature detected by sensor 1 is 31.5 and temperature is abnormal, and at sensor 2 is 32.5 degrees and temperature is in the safe temperature. When the abnormal temperature status is not occurred the data become "_00.0S". When the projector is reset, "_00.0S" is set. Every time abnormal temperature status is detected, it renews the data and returns it. It only returns the renewed data of the latest abnormal temperature and the previous data is cleared. Unacceptable "?" [CR] 46 / 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

PDG-DWL100
Expand Serial Command Functional Specifications
46 / 47
9.12.5 CR_TEMPWARN Command
Command
“CR_TEMPWARN” [CR]
Details
Get the information about the temperature inside the projector
(1) close to an abnormal status 2) in an abnormal status 3) temperature
level is normal 4)abnormal status is not detected).
Possible to get data from plural sensor s at once.
Correspondence
Acceptable
“000_%1” [CR]
%1
“*_*”
Sensor 1 data comes first, and then one space, after that
sensor 2 data is followed.
Each data is as below:
“W”--- in or close to the abnormal temp. (Warning Temp.)
“S”--- in the safe level of temperature (Safe Temp.).
“N”--- the given sensor does not detect abnormal temp.
e.g. “S_W” [CR] indicates that the temperature detected at
Sensor 1 is in the safe level while Sensor 2 in the abnormal
temperature.
Unacceptable
“?” [CR]
9.12.6 CR_TEMPFAIL Command
Command
“CR_TEMPFAIL” [CR]
Details
Get the temperature inside the projector when the abnormal status occurs.
Possible to get the data from plural sensors at once.
Correspondence
Acceptable
“000_%1” [CR]
%1
e.g. “_31.5F”[CR]
_ indicates a space.
When the temperature goes under 0, the first character
become “-”, such as “-05.5F”.
With more than one temperature sensors installed, projector
returns the data of each sensor in order.
e.g. “_31.5F_35.2S” [CR]
The first data indicates sensor 1, then sensor 2 data follows
after single space.
Last character in each data indicates the status of
temperature;
In the abnormal temperature --------------------- “F”
In the safe level of temperature ------------------- “S”
Neither in or close to the abnormal temp. ------- “N”
The second example above indicates that the temperature
detected by sensor 1 is 31.5 and temperature is abnormal,
and at sensor 2 is 32.5 degrees and temperature is in the
safe temperature.
When the abnormal temperature status is not occurred the
data become “_00.0S”.
When the projector is reset, “_00.0S” is set.
Every time abnormal temperature status is detected, it
renews the data and returns it.
It only returns the renewed
data of the latest abnormal temperature and the previous
data is cleared.
Unacceptable
“?” [CR]