MUTE LOCK menu item
View all Sennheiser EW-D SKP manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
EW-D EM rack receiver ► ▷ Press the UP or DOWN button to adjust the value. Make sure that the signal in the next device in the signal chain (e.g. mixing console, power amplifier, guitar amplifier, etc.) is not overdriven. ▷ Press the SET button to save the set value. Recommended settings for a unity gain link: Unity gain refers to the configuration where the audio signal arriving at a device leaves the device with the same level. Example: If you are using an EW-D wireless link instead of a guitar cable, with unity gain settings, the volume of the guitar in the guitar amplifier will be as high as it would be if using a guitar cable. Possible unity gain settings: ▷ AF Out 18 dB | Gain 27 dB ▷ AF Out 12 dB | Gain 33 dB ▷ AF Out 6 dB | Gain 39 dB MUTE LOCK menu item Under the MUTE LOCK menu item, you can disable the mute switch on the paired transmitter. The transmitter can then no longer be muted. ▷ Open the MUTE LOCK menu item. The item flashes on the display as follows. ► ▷ Press the UP or DOWN button to enable or disable the function. If the following icon appears on the display, the transmit62