Sharp XG-C55X XG-C55X Operation Manual - Page 90
Removing and Installing the Lamp Unit, put the projector into - user manual
UPC - 074000364219
View all Sharp XG-C55X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 90 highlights
Regarding the Lamp Removing and Installing the Lamp Unit Info • Be sure to remove the lamp unit by the handle. Be sure not to touch the glass surface of the lamp unit or the inside of the projector. • To avoid injury to yourself and damage to the lamp, be sure to carefully follow the steps below. • Do not loosen other screws except for the lamp unit cover and lamp unit. (Only the silver screws are loosened). • Please refer to the installation manual included with the lamp unit. 1 Press STANDBY on the projector or on the remote control to put the projector into the standby mode. • Wait until the cooling fan stops. Warning! • Do not remove the lamp unit from the projector right after use. The lamp will be very hot and may cause burn or injury. 2 Disconnect the power cord. • Unplug the power cord from the AC socket. • Leave the lamp until it has fully cooled down (about 1 hour). 3 Change the air filter. • Change the air filter whenever you install the lamp unit (see pages 81 and 82). 4 Remove the lamp unit cover. • Loosen the user service screw that secures the lamp unit cover. Then open the cover in the direction of the arrow. -86 Lamp unit BQC-XGC55X//1 STANDBY button STANDBY button AC socket User service screw