Setup "- - - - " appears in the SHUTTER display five seconds after setting. Area settings are stored and the units switches to normal mode. Area Settings Before using the unit When you use this unit for the first time, area setting is required. Setting the area SW1, SW2 buttons PANEL ACTIVE button SHUTTER display UP/DOWN lever LOCK switch POWER switch 1 Turn the power on. 2 Set the LOCK switch to OFF and make sure that the PANEL ACTIVE button is not illuminated. If the PANEL ACTIVE button lights up, press the button to turn the light off. 3 Press and hold down the SW1 and SW2 buttons at the same time for more than two seconds. The unit switches to setting mode and selectable setting values appear in the SHUTTER display. 4 Release the buttons after the unit switches to setting mode. 5 Select the desired area, using the UP/DOWN lever, within five seconds after the unit switches to setting mode. Setting 60i5 60i 50i Area NTSC (except Japan) a) NTSC (Japan) b) PAL c) a) NTSC composite video signal output with black setup (7.5 IRE). System frequency: 59.94i b) NTSC composite video signal output with no black setup. System frequency: 59.94i c) PAL composite video signal output. System frequency: 50i Note Setting mode is deactivated unless setup starts within five seconds after the unit switches to setting mode. Follow step 3 again to activate setting mode. Settings when Connecting with Only Single-Mode Optical Fiber Cable LASER DIODE (optical output) setting When you use only single-mode optical fiber cable to connect the HD camera adaptor to this unit, configure the optical output setting in the unit. Setting LASER DIODE 1 Connect the unit and the HD camera adaptor by a single-mode optical fiber cable. 2 Set the POWER switch of this unit to ON. 3 Display the menu. For information about setting menu items, see "Setup Menu" (page 19). 4 Set the optical output to ON. Display the S01 page of the SYSTEM OPERATION menu, then set LASER DIODE to ON. Notes • This setting is unnecessary when you use optical composite cables. • In the factory default setting, LASER DIODE is set to OFF when this unit starts up. If you want to retain the LASER DIODE setting you have previously set, from the CCU CONFIGURATION menu, select C14 page, LASER DIODE ON BACKUP, then set to ENABLE. • Use general, single-mode optical fiber cables with an LC connector for connection. For details, contact a Sony sales representative. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

12
Setup
Area Settings
Before using the unit
When you use this unit for the first time, area setting is
required.
Setting the area
1
Turn the power on.
2
Set the LOCK switch to OFF and make sure that the
PANEL ACTIVE button is not illuminated.
If the PANEL ACTIVE button lights up, press the button to
turn the light off.
3
Press and hold down the SW1 and SW2 buttons at the
same time for more than two seconds.
The unit switches to setting mode and selectable setting
values appear in the SHUTTER display.
4
Release the buttons after the unit switches to setting
mode.
5
Select the desired area, using the UP/DOWN lever,
within five seconds after the unit switches to setting
mode.
a) NTSC composite video signal output with black setup (7.5 IRE).
System frequency: 59.94i
b) NTSC composite video signal output with no black setup. System
frequency: 59.94i
c) PAL composite video signal output. System frequency: 50i
Setting mode is deactivated unless setup starts within five
seconds after the unit switches to setting mode. Follow step 3
again to activate setting mode.
“- - - - ” appears in the SHUTTER display five seconds after
setting. Area settings are stored and the units switches to
normal mode.
Settings when Connecting with Only
Single-Mode Optical Fiber Cable
LASER DIODE (optical output) setting
When you use only single-mode optical fiber cable to connect
the HD camera adaptor to this unit, configure the optical output
setting in the unit.
Setting LASER DIODE
1
Connect the unit and the HD camera adaptor by a
single-mode optical fiber cable.
2
Set the POWER switch of this unit to ON.
3
Display the menu.
For information about setting menu items, see
“Setup
Menu” (page 19)
.
4
Set the optical output to ON.
Display the <OUTPUT SELECT> S01 page of the
SYSTEM OPERATION menu, then set LASER DIODE to
ON.
This setting is unnecessary when you use optical composite
cables.
In the factory default setting, LASER DIODE is set to OFF
when this unit starts up. If you want to retain the LASER
DIODE setting you have previously set, from the CCU
CONFIGURATION menu, select <OTHERS> C14 page,
LASER DIODE ON BACKUP, then set to ENABLE.
Use general, single-mode optical fiber cables with an LC
connector for connection. For details, contact a Sony sales
representative.
Setting
Area
60i5
NTSC (except Japan)
a)
60i
NTSC (Japan)
b)
50i
PAL
c)
Note
SW1, SW2 buttons
LOCK switch
POWER switch
SHUTTER display
PANEL ACTIVE button
UP/DOWN lever
Notes