OPTICAL CONDITION CAM/CCU optical reception, CAM POWER indicator

Page 8 highlights

Pressing the CONTROL knob performs the same function as setting the CANCEL/ENTER lever to the ENTER position. e PANEL ACTIVE button Activates the control panel to control the camera connected to the CCU (panel active state). When the button is lit, the IRIS/MB ACTIVE indicator also turns on simultaneously. When the button is not lit, the panel is deactivated (panel lock state) to prevent inadvertent operation. f SW1, SW2 (assignable switch 1, 2) buttons Controls the function assigned to each button on the page in the CCU CONFIGURATION menu. The button light turns on/off as the assigned function is switched on/off. For details, see "ASSIGNABLE/CUSTOM" (page 31) on . g BARS (color bars) button Switches on the color bar signal output to the monitor connected to the CCU (button light turns on). Pressing the button again restores the previous signal output. h STANDARD button Stores the current camera settings as the reference file data values in the camera (button light turns on for a few seconds). While the button is lit, pressing the button again cancels the operation and restores the previous data values. i SHUTTER control block Controls the shutter settings. ON button ECS (extended clear scan) button Display UP/DOWN lever ECS SHUTTER UP ON DOWN • ON button Switches the normal shutter function, extended clear scan function, or slow shutter function on/off (button light turns on/off). • ECS (extended clear scan) button Switches the extended clear scan mode on/off (button light turns on/off). • Display When the ECS button is lit: Displays the clear scan frequency. When the ECS button is not lit: Displays the shutter speed. The indicator is not displayed when auto shutter is on. • UP/DOWN lever When the ECS button is lit: Adjusts the clear scan frequency. UP increases the frequency, and DOWN decreases the frequency. When the ECS button is not lit: Adjusts the shutter speed. UP increases the shutter speed, and DOWN decreases the shutter speed. The number of frames at slow shutter speed increases when the lever is in the UP position, and decreases in the DOWN position. Holding the lever UP or DOWN advances the setting in that direction. j MASTER GAIN control block Controls the video output signal gain in response to the lighting of the subject. Display UP/DOWN lever MASTER GAIN UP DOWN • Display Displays the video output signal gain setting (dB units). The indicator is not displayed when auto gain (AGC) is on. • UP/DOWN lever Adjusts the video output signal gain setting (dB units). UP increases the gain, and DOWN decreases the gain. Holding the lever UP or DOWN advances the setting in that direction. k ALARM indicator Lights up red to indicate an error in the CCU or camera system. l OPTICAL CONDITION CAM/CCU (optical reception) indicator The CAM indicator shows the reception status of the connected camera adaptor, and the CCU indicator shows the reception status of the unit. Green: The reception level is good. Orange: The reception level is low. Red: The reception level is extremely low. Off: A transmission error has occurred. m POWER switch Switches the power for the entire system on and off, including the CCU, camera, and the RCP-1000-series Remote Control Panel connected to the REMOTE connector on the rear panel. Pressing the "?" side turns the camera system on, and pressing the "a" side turns it off. n CAM POWER indicator Turns on when power is supplied to the camera. o LOCK switch Locks the buttons on the front panel. Select the desired buttons to be locked on the page in the CCU CONFIGURATION menu. For details, see "" (page 32). p NETWORK indicator Displays the network system connection status. On: Indicates that external control equipment (RCP-1000- series Remote Control Panel or other device) is connected. Flashing: Indicates a connection problem with the external control equipment (RCP-1000-series Remote Control Panel or other device). Off: Indicates that a LAN cable is not connected or that the network system connection parameters have not been set. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

8
Pressing the CONTROL knob performs the same function as
setting the CANCEL/ENTER lever to the ENTER position.
e
PANEL ACTIVE button
Activates the control panel to control the camera connected to
the CCU (panel active state). When the button is lit, the
IRIS/MB ACTIVE indicator also turns on simultaneously.
When the button is not lit, the panel is deactivated (panel lock
state) to prevent inadvertent operation.
f
SW1, SW2 (assignable switch 1, 2) buttons
Controls the function assigned to each button on the <FRONT
PANEL 1> page in the CCU CONFIGURATION menu. The
button light turns on/off as the assigned function is switched
on/off.
For details, see “ASSIGNABLE/CUSTOM” (page 31) on
<FRONT PANEL 1>.
g
BARS (color bars) button
Switches on the color bar signal output to the monitor
connected to the CCU (button light turns on). Pressing the
button again restores the previous signal output.
h
STANDARD button
Stores the current camera settings as the reference file data
values in the camera (button light turns on for a few seconds).
While the button is lit, pressing the button again cancels the
operation and restores the previous data values.
i
SHUTTER control block
Controls the shutter settings.
ON button
Switches the normal shutter function, extended clear scan
function, or slow shutter function on/off (button light turns
on/off).
ECS (extended clear scan) button
Switches the extended clear scan mode on/off (button light
turns on/off).
• Display
When the ECS button is lit: Displays the clear scan frequency.
When the ECS button is not lit: Displays the shutter speed.
The indicator is not displayed when auto shutter is on.
UP/DOWN lever
When the ECS button is lit: Adjusts the clear scan frequency.
UP increases the frequency, and DOWN decreases the
frequency.
When the ECS button is not lit: Adjusts the shutter speed. UP
increases the shutter speed, and DOWN decreases the
shutter speed.
The number of frames at slow shutter speed increases when
the lever is in the UP position, and decreases in the DOWN
position.
Holding the lever UP or DOWN advances the setting in that
direction.
j
MASTER GAIN control block
Controls the video output signal gain in response to the
lighting of the subject.
• Display
Displays the video output signal gain setting (dB units).
The indicator is not displayed when auto gain (AGC) is on.
UP/DOWN lever
Adjusts the video output signal gain setting (dB units).
UP increases the gain, and DOWN decreases the gain.
Holding the lever UP or DOWN advances the setting in that
direction.
k
ALARM indicator
Lights up red to indicate an error in the CCU or camera
system.
l
OPTICAL CONDITION CAM/CCU (optical reception)
indicator
The CAM indicator shows the reception status of the
connected camera adaptor, and the CCU indicator shows the
reception status of the unit.
Green:
The reception level is good.
Orange:
The reception level is low.
Red:
The reception level is extremely low.
Off:
A transmission error has occurred.
m
POWER switch
Switches the power for the entire system on and off, including
the CCU, camera, and the RCP-1000-series Remote Control
Panel connected to the REMOTE connector on the rear panel.
Pressing the “
?
” side turns the camera system on, and
pressing the “
a
” side turns it off.
n
CAM POWER indicator
Turns on when power is supplied to the camera.
o
LOCK switch
Locks the buttons on the front panel. Select the desired
buttons to be locked on the <FRONT PANEL 3> page in the
CCU CONFIGURATION menu.
For details, see “<FRONT PANEL 3>” (page 32).
p
NETWORK indicator
Displays the network system connection status.
On:
Indicates that external control equipment (RCP-1000-
series Remote Control Panel or other device) is
connected.
Flashing:
Indicates a connection problem with the external
control equipment (RCP-1000-series Remote Control
Panel or other device).
Off:
Indicates that a LAN cable is not connected or that the
network system connection parameters have not been set.
ECS
ON
DOWN
UP
SHUTTER
ON button
ECS (extended clear scan) button
UP/DOWN lever
Display
DOWN
UP
MASTER GAIN
UP/DOWN lever
Display