Switched (daisy chain) connection, Redundant connection
View all TASCAM DA-6400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
Switched (daisy chain) connection Dante devices can be daisy-chained when there are few connected devices and when not using a switching hub. Connect them as shown below. 88Switched (daisy chain) connection example 88Redundant connection example Primary Secondary Mixer PC Mixer IF-DA64 / DA-6400 IF-DA64 / DA-6400 HUB IF-DA64 / DA-6400 HUB NOTE • When using a switched (daisy chain) connection, connect to either the PRIMARY or SECONDARY connector. • If the number of connected devices increases, raising the latency setting will be necessary. Redundant connection For recording situations where retakes are not possible, including live performances, a connection set up like the following uses two completely independent primary and secondary networks. IF-DA64 / DA-6400 NOTE Settings for switched (daisy chain) and redundant connections do not change automatically. Change the settings on the Dante Controller Network Config screen. CAUTION • The primary and secondary networks cannot be connected to each other in any way. • Do not connect the primary and secondary networks to the same switching hub. Hub Primary Secondary 9 TASCAM IF-DA64