TP-Link TL-SG3210 TL-SG3210 V1 CLI Reference Guide - Page 141
acl edit time-segment
View all TP-Link TL-SG3210 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 141 highlights
Command Mode Global Configuration Mode Example Add a time-range named tSeg1, with time from 8:30 to 12:00 at working day: TP-LINK(config)# acl time-segment tSeg1 start-time 08:30 end-time 12:00 week-day working-day acl edit time-segment Description The acl edit time-segment command is used to edit Time-Range. Syntax acl edit time-segment {name} [start-time start-time] [end-time end-time] [week-day week-day] [start-date start-date] [end-date end-date] [holiday {disable | enable}] Parameter name -- The Time-Range name, ranging from 1 to 16 characters. start-time -- The start time of the time-slice, in the format of HH:MM. By default, it is 00:00. end-time -- The end time of the time-slice, in the format of HH:MM. By default, it is 23:59. week-day - - Period Mode, in the format of 1-3,6 or daily, off-day, working-day. 1-3, 6 represent Monday, Tuesday, Wednesday and Saturday; daily represents every day; off-day represents weekend and working-day represents working day. By default, the period mode is disabled. start-date - - The start date in Absoluteness Mode, in the format of MM/DD/YYYY. By default, it is 01/01/1970. end-date - - The end date in Absoluteness Mode, in the format of MM/DD/YYYY. By default, it is 12/31/2099. The absoluteness mode will be disabled if the start date and end date are both not configured. holiday -- Enable/ Disable Holiday Mode. By default, it is disabled. Command Mode Global Configuration Mode Example Edit the time-range named tSeg1, with time from 8:30 to 12:00 at working day: 129