Thermador T36BB110SS View Kitchen Design and Planning Guide - Page 20

Pro Grand, Optional Accessories, Planning Information

Page 20 highlights

PRO GRAND® OPTIONAL ACCESSORIES 27-Inch Commercial-Depth, Professional 36-Inch, Dual-Fuel 36-Inch, Gas PRD364WDGU PRD366WGU PRD364WIGU PRG364WDG PRG366WG PWOKRINGHC - Wok Ring PA12CHPBLK - Chopping Block / Cutting Board PAGRIDDLE - Professional Griddle, Sits on Top of Grates Over 2 Star Burners, High-Release Coating PA12GRILLW - 12" Pro Grill Plate with Tray, (for Griddle Models), Non-Fusion Coating PAGRIDLFW - 12" Pro Griddle with Tray, (Fusion Coating Option for Griddle Models) PA12GRILFW - 12" Grill Plate with Tray (for Griddle Models), Fusion Coating PA12LCVRW - 12" Professional Griddle Cover PA36WLBG - 7" Low Backguard* PA36WTKG - Toekick PARKB36CGY - Blue Knob Kit PARKB36IGY - Blue Knob Kit PARKB36GY - Blue Knob Kit PALPKITDGW - LP Conversion Kit, Pro Grand Dual Fuel Models with 4 and 6 Burners PALPKITGGW - LP Conversion Kit, Pro Grand Gas Models with 4 and 6 Burners PAALTKITGW - High Altitude Kit, Natural Gas or Dual-Fuel Pro Grand Ranges, 5,400 ft. to 10,200 ft. Contact Customer Support - High Altitude Kit, Gas or Dual-Fuel Pro Grand Ranges Connected to LP Gas, 10,000 ft. to 10,200 ft. TEPPAN1016 - Liberty® Induction Teppanyaki | THERMADOR | RANGES CHEFSPAN08 - 10" Stainless Steel Pan TROASTERT - Stainless Steel Roaster Pan *Models PCG305xx, PRD305xx, PRD606xx, PRG305xx, PRG304xx, PRD304xx, PRx488xx, PRIxxxxxx are suitable for 0" rear clearance to combustible surfaces. All other models: when using the included Island Trim a minimum 6" (152 mm) rear clearance is required to a combustible surface. When installing against a combustible surface, a Thermador® Low Backguard is required for a 0" rear clearance to the combustible surface. A Thermador Low Backguard must be purchased separately. A rear clearance to a surface covered in a noncombustible material (metal, ceramic tile, brick, marble, or stone) is 0" when using the included Island Trim. Clearances of less than 6" (152 mm) should be approved by the local codes and/or by the local authority having 36 jurisdiction. Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA. PRO GRAND® PLANNING INFORMATION Professional Ranges Model Options There are three sizes of Thermador Pro Grand Ranges to choose from - 60-inch, 48-inch and 36-inch. Models are available in your choice of all-gas or dual-fuel configurations. All models are 27-inches deep and available in stainless steel with a porcelain cooktop surface. Ranges are LP convertible by ordering the specified kit. Be sure to reference the correct model information in this design guide. Installation Considerations The information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Pro Grand Range, be sure to verify the cutout dimensions and electrical / gas connections. Installation instructions are subject to change. Always consult with the installation manual included with the product for complete details prior to the installation. Installation Options Thermador Pro Grand Ranges feature a bold, professional design and a commercial-depth of 27-inches. These ranges can be installed in a wall or island installation. Ventilation Requirements We strongly recommend that a Thermador Professional® Wall or Island Hood or Custom Insert be installed with all Thermador Pro Grand Ranges. Reference the selection guide in the ventilation section for compatible Thermador hoods. Downdraft ventilation should not be used. Do not install a microwave-hood combination above the cooktop, as these types of units do not provide the proper ventilation and are not suitable for use with Thermador Pro Grand Ranges. Important Ventilation Notes: • For wall installations, the hood width must, at a minimum, equal the nominal width of the appliance cooking surface. Where space permits, a hood larger in width than the cooking surface may be desirable for improved ventilation performance. • For island installations, the hood width should, at a minimum, overhang the appliance cooking surface by 3" on each side. • Due to the high heat capability of these cooktops, particular attention should be paid to the hood and duct work installation to assure it meets local building codes. • For best smoke elimination, the lower edge of the hood should be installed 30"-36" above the appliance cooking surface. • If the hood contains any combustible materials (i.e., a wood covering), it must be 36" or greater distance above the cooking surface. Electrical and Gas Specifications Be sure your appliance is properly installed and grounded by a qualified technician. Installation, electrical and gas connections, and grounding must comply with all applicable local codes. Natural Gas or LP Thermador Dual-Fuel Pro Grand Ranges are shipped by the factory to operate on natural gas. They must be converted for use with propane. Verify that the type of gas being used at the installation site matches the type of gas used by the appliance. If the location / job site requires conversion from natural gas to propane (LP), order the specified LP conversion kit. Field conversion must be done by qualified service personnel only. Please refer to the LP Conversion Instructions for further information. A manual gas shut-off valve must be installed external to the appliance, in a location accessible from the front, for the purpose of shutting off the gas supply. The supply line must not interfere with the back of the unit. Natural Gas Requirements: • Inlet Connection: 3/4" NPT external, 1/2" NPT internal (Minimum 3/4" diam. flex line) • Supply Pressure: 6" min. to 14" max. water column (14.9 to 34.9 mb) • Manifold Pressure: 5" water column (12.5 mb) Propane Gas Requirements: • Inlet Connection: 3/4" NPT external, 1/2" NPT internal (Minimum 3/4" diam. flex line) • Supply Pressure: 11" min. to 14" max. water column (27.4 mb to 34.9 mb) • Manifold Pressure: 10" water column (24.9 mb) High Altitude: High altitude kits are available for Thermador Pro Harmony Ranges. Reference the Accessory chart or Contact Customer Support for details. Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone 37 | THERMADOR | RANGES

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131

37
|
THERMADOR
|
RANGES
36
|
THERMADOR
|
RANGES
PRO GRAND
®
OPTIONAL ACCESSORIES
27-Inch Commercial-Depth, Professional
36-Inch, Dual-Fuel
36-Inch, Gas
PRD364WDGU
PRD366WGU
PRD364WIGU
PRG364WDG
PRG366WG
PWOKRINGHC
– Wok Ring
PA12CHPBLK
– Chopping Block / Cutting Board
PAGRIDDLE
– Professional Griddle, Sits on Top of Grates
Over 2 Star Burners, High-Release Coating
PA12GRILLW
– 12" Pro Grill Plate with Tray, (for Griddle
Models), Non-Fusion Coating
PAGRIDLFW
– 12" Pro Griddle with Tray, (Fusion Coating
Option for Griddle Models)
PA12GRILFW
– 12" Grill Plate with Tray (for Griddle Models),
Fusion Coating
PA12LCVRW
– 12" Professional Griddle Cover
PA36WLBG
– 7" Low Backguard*
PA36WTKG
– Toekick
PARKB36CGY
– Blue Knob Kit
PARKB36IGY
– Blue Knob Kit
PARKB36GY
– Blue Knob Kit
PALPKITDGW
– LP Conversion Kit, Pro Grand Dual Fuel
Models with 4 and 6 Burners
PALPKITGGW
– LP Conversion Kit, Pro Grand Gas Models
with 4 and 6 Burners
PAALTKITGW
– High Altitude Kit, Natural Gas or Dual-Fuel Pro Grand
Ranges, 5,400 ft. to 10,200 ft.
Contact Customer Support
– High Altitude Kit, Gas or Dual-Fuel Pro
Grand Ranges Connected to LP Gas, 10,000 ft. to 10,200 ft.
TEPPAN1016
– Liberty
®
Induction Teppanyaki
CHEFSPAN08
– 10" Stainless Steel Pan
TROASTERT
– Stainless Steel Roaster Pan
*Models PCG305xx, PRD305xx, PRD606xx, PRG305xx, PRG304xx, PRD304xx, PRx488xx, PRIxxxxxx are suitable for 0" rear clearance to combustible surfaces. All other models: when using
the included Island Trim a minimum 6" (152 mm) rear clearance is required to a combustible surface. When installing against a combustible surface, a Thermador
®
Low Backguard is required
for a 0" rear clearance to the combustible surface. A Thermador Low Backguard must be purchased separately. A rear clearance to a surface covered in a noncombustible material (metal,
ceramic tile, brick, marble, or stone) is 0" when using the included Island Trim. Clearances of less than 6" (152 mm) should be approved by the local codes and/or by the local authority having
jurisdiction. Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA.
Model Options
There are three sizes of Thermador Pro Grand Ranges to choose
from — 60-inch, 48-inch and 36-inch. Models are available in your choice
of all-gas or dual-fuel configurations. All models are 27-inches deep and
available in stainless steel with a porcelain cooktop surface. Ranges are
LP convertible by ordering the specified kit. Be sure to reference the
correct model information in this design guide.
Installation Considerations
The information in this design guide provides key features, product
dimensions, cutouts and installation specifications. Before installing a
Thermador Pro Grand Range, be sure to verify the cutout dimensions
and electrical / gas connections. Installation instructions are subject to
change. Always consult with the installation manual included with the
product for complete details prior to the installation.
Installation Options
Thermador Pro Grand Ranges feature a bold, professional design and a
commercial-depth of 27-inches. These ranges can be installed in a wall
or island installation.
Ventilation Requirements
We strongly recommend that a Thermador Professional
®
Wall or Island
Hood or Custom Insert be installed with all Thermador Pro Grand
Ranges. Reference the selection guide in the ventilation section for
compatible Thermador hoods. Downdraft ventilation should not be
used. Do not install a microwave-hood combination above the cooktop,
as these types of units do not provide the proper ventilation and are not
suitable for use with Thermador Pro Grand Ranges.
Important Ventilation Notes:
For wall installations, the hood width must, at a minimum, equal the
nominal width of the appliance cooking surface. Where space permits,
a hood larger in width than the cooking surface may be desirable for
improved ventilation performance.
For island installations, the hood width should, at a minimum,
overhang the appliance cooking surface by 3" on each side.
Due to the high heat capability of these cooktops, particular attention
should be paid to the hood and duct work installation to assure it
meets local building codes.
For best smoke elimination, the lower edge of the hood should be
installed 30"–36" above the appliance cooking surface.
If the hood contains any combustible materials (i.e., a wood covering),
it must be 36" or greater distance above the cooking surface.
Electrical and Gas SpeciFcations
Be sure your appliance is properly installed and grounded by a qualified
technician. Installation, electrical and gas connections, and grounding
must comply with all applicable local codes.
Natural Gas or LP
Thermador Dual-Fuel Pro Grand Ranges are shipped by the factory to
operate on natural gas. They must be converted for use with propane.
Verify that the type of gas being used at the installation site matches
the type of gas used by the appliance. If the location / job site requires
conversion from natural gas to propane (LP), order the specified LP
conversion kit. Field conversion must be done by qualified service
personnel only. Please refer to the LP Conversion Instructions for further
information.
A manual gas shut-off valve must be installed external to the appliance,
in a location accessible from the front, for the purpose of shutting off
the gas supply. The supply line must not interfere with the back of
the unit.
Natural Gas Requirements:
Inlet Connection:
3
/
4
" NPT external,
1
/
2
" NPT internal
(Minimum
3
/
4
" diam. flex line)
Supply Pressure: 6" min. to 14" max. water column
(14.9 to 34.9 mb)
Manifold Pressure: 5" water column (12.5 mb)
Propane Gas Requirements:
Inlet Connection:
3
/
4
" NPT external,
1
/
2
" NPT internal
(Minimum
3
/
4
" diam. flex line)
Supply Pressure: 11" min. to 14" max. water column
(27.4 mb to 34.9 mb)
Manifold Pressure: 10" water column (24.9 mb)
High Altitude:
High altitude kits are available for Thermador Pro Harmony Ranges.
Reference the Accessory chart or Contact Customer Support for details.
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone
PRO GRAND
®
PLANNING INFORMATION
Professional Ranges