Thermador T36BB110SS View Kitchen Design and Planning Guide - Page 22
Pro Grand, Installation
View all Thermador T36BB110SS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
PRO GRAND® INSTALLATION Professional Ranges 60-Inch, 48-Inch and 36-Inch Range Dimensions and Clearance Requirements With "Low Back" NOTE: A 36-inch minimum clearance is required between the top of the cooking surface and the bottom of an unprotected cabinet. A 30-inch clearance can be used when the bottom of the wood or metal cabinet is protected by not less than 1/4 inch of a flame retardant material covered with not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. 36" (914 mm) min. to combustible materials 30 5/8" (778 mm) 29 3/8" (746 mm) Combustible Materials 7" (178 mm) Lowback 357/8" (911 mm) Min. 36¾" (933 mm) Max. 251/8" (638 mm) max. recess depth Combustible Back Wall 25 3/4" (654 mm) 491/8" (1248 mm) 60-Inch Pro Grand Ranges are suitable for 0" rear clearance to combustible surfaces. All other models: when using the included Island Trim a minimum 6" (152 mm) rear clearance is required to a combustible surface. When installing against a combustible surface, a Thermador® Low Backguard is required for a 0" rear clearance to the combustible surface. A Thermador Low Backguard must be purchased separately. A rear clearance to a surface covered in a noncombustible material (metal, ceramic tile, brick, marble, or stone) is 0" when using the included Island Trim. Clearances of less than 6" (152 mm) should be approved by the local codes and/or by the local authority having jurisdiction. Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA. PRO GRAND® INSTALLATION Professional Ranges 60-Inch, 48-Inch and 36-Inch Range Dimensions and Clearance Requirements With "Flush Island Trim" Combustible Materials 36" (914 mm) min. to combustible materials 36" and 48" models only: 6" (152 mm) min. to cocmobmubsutisbtlieblseusrfuarcfaece wiwthitFhluFsluhsIhslIasnladnTdriTmrim 36" and 48" models only: Shaded area behind range indicates minimum clearance to combustible surfaces, combustible materials cannot be located within this area. 357/8" (911 mm) Min. 36¾" (933 mm) Max. 30 5/8" (778 mm) 29 3/8" (746 mm) 251/8" (638 mm) max. recess depth For Flush Island Trim installations, counter surface should have a cantilever edge meeting the back section of the Flush Island Trim accessory. Combustible Back Wall If an inner wall is used under the cantilever counter top, there should be a 1/8" (3 mm) gap from the rear of the range to the inner wall. 25 3/4" (654 mm) 49 1/8" (1248 mm) 60-Inch Pro Grand Ranges are suitable for 0" rear clearance to combustible surfaces. All other models: when using the included Island Trim a minimum 6" (152 mm) rear clearance is required to a combustible surface. When installing against a combustible surface, a Thermador® Low Backguard is required for a 0" rear clearance to the combustible surface. A Thermador Low Backguard must be purchased separately. A rear clearance to a surface covered in a noncombustible material (metal, ceramic tile, brick, marble, or stone) is 0" when using the included Island Trim. Clearances of less than 6" (152 mm) should be approved by the local codes and/or by the local authority having jurisdiction. Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA. | THERMADOR | RANGES | THERMADOR | RANGES 40 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone 41