Thermador T36BB110SS View Kitchen Design and Planning Guide - Page 25

Professional Rangetops, Optional Accessories, Planning Information

Page 25 highlights

PROFESSIONAL RANGETOPS OPTIONAL ACCESSORIES 48-Inch 36-Inch 30-Inch PCG486WD PCG364WD PCG366W PCG305W PA48WLBC - 10" Backguard, 48" Rangetop PA36WLBC - 10" Backguard, 36" Rangetop PA30WLBC - 10" Backguard, 30" Rangetop PAGRIDDLE Griddle Sits on Top of Grates Over 2 Star Burners, Non-Stick High-Release Coating PA12GRILLW 12" Pro Grill with Tray, (for Griddle Models), Non-Stick HighRelease Coating PAGRIDLFW 12" Pro Griddle with Tray, (for Griddle Models), Fusion Coating PA12GRILFW 12" Pro Grill with Tray (for Griddle Models), Fusion Coating PA12LCVRW 12" Pro Griddle Cover (for Griddle Models) PWOKRINGHC Wok Ring PAKNOBLUWR Metallic Blue Knob Kit PA12CHPBLK 12" Chopping Block / Cutting Board PALPKITHW LP Conversion Kit, Pro Rangetop Models with 4 and 6 Burners PALPKITHW5 LP Conversion Kit, Pro Rangetop 5 Burner Model Only PAALTKITH High Altitude Kit, Natural Gas Pro Rangetops, 5,400 ft. to 10,200 ft. | THERMADOR | RANGETOPS 46 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone PLANNING INFORMATION Professional Rangetops Model Options There are three sizes of Thermador Professional® Rangetops to choose from - 30-inch, 36-inch and 48-inch. Models are available with various rangetop configurations. Every model is LP convertible by ordering a conversion kit. Be sure to reference the correct model information in this design guide. Installation Considerations The information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Professional Rangetop, be sure to verify the cutout dimensions and electrical / gas connections. Installation instructions are subject to change. Always consult with the installation manual included with the product for complete details prior to the installation. Installation Options To ensure professional results, the cabinet and countertop openings should be prepared by a qualified cabinet worker. The rangetop can be installed in various positions with the front either flush or projecting, depending on the countertop's depth. The rangetop is designed to hang from the countertop by its side flanges. The countertop however, must be strong enough to support the rangetop. It may be necessary to add a supporting cleat along each side or a 2" x 4" corner brace. Another alternative would be to construct a deck to set the rangetop on. Consult with the installation manual packed with the product for complete details before installing. Above a Warming Drawer Thermador Professional Rangetops may be installed above a Thermador Warming Drawer to create a convenient cooking center. A minimum 2 3/4" (70 mm) clearance is required between the bottom of the rangetop and the top of the warming drawer. Refer to the warming drawer section for additional specifications. Rear Clearance Requirements 30-Inch model PCG305W is suitable for 0" rear clearance to combustible surfaces. All other models must meet these clearances: Thermador recommends a minimum 6" (152 mm) rear clearance to a combustible surface. Clearances of less than 6" must be approved by the local codes and / or by the local authority having jurisdiction. When installing against a combustible surface, a Thermador Low Backguard (purchased separately) is required for a 0" rear clearance to the combustible surface. Electrical and Gas Specifications Be sure your appliance is properly installed and grounded by a qualified technician. Installation, electrical and gas connections, and grounding must comply with all applicable local codes. Thermador Professional® Rangetops are equipped with a 3-wire plug and are designed to be connected to a 120V AC, 60 Hz, single-phase power supply. A dedicated circuit breaker is required. Model PCG486WD PCG364WD PCG366W PCG305W Required Circuit Breaker 120V AC, 60Hz 20 A 20 A 15 A 15 A Electrical Supply The cord supplied with the gas ranges having an electric griddle requires a NEMA 5-20 receptacle. All other gas units require a NEMA 5-15 receptacle. Gas Requirements and Hookup Rangetops are shipped by the factory to operate on natural gas. They must be converted for use with propane. Verify that the type of gas being used at the installation site matches the type of gas used by the appliance. If the location / job site requires conversion from natural gas to propane (LP), order the specified LP conversion kit. Field conversion must be done by qualified service personnel only. Please refer to the LP Conversion Instructions for further information. Natural Gas Requirements: • Inlet Connection: 1/2" NPT internal (Minimum 3/4" dia. flex line) • Supply Pressure: 6" min. to 14" max. water column (14.9 to 34.9 mb) • Manifold Pressure: 5" water column (12.5 mb) Propane Gas Requirements: • Inlet Connection: 1/2" NPT internal (Minimum 3/4" dia. flex line) • Supply Pressure: 11" min. to 14" max. water column (27.4 mb to 34.9 mb) • Manifold Pressure: 10" water column (24.9 mb) A manual gas shut-off valve must be installed external to the appliance, in a location accessible from the front, for the purpose of shutting off the gas supply. The supply line must not interfere with the back of the unit. High Altitude High altitude kits are available for Thermador Pro Rangetops. Reference the Accessory chart or Contact Customer Support for details. 47 | THERMADOR | RANGETOPS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131

47
46
|
THERMADOR
|
RANGETOPS
|
THERMADOR
|
RANGETOPS
PROFESSIONAL RANGETOPS
OPTIONAL ACCESSORIES
PLANNING INFORMATION
Professional Rangetops
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone
48-Inch
36-Inch
30-Inch
PCG486WD
PCG364WD
PCG366W
PCG305W
PA48WLBC
– 10" Backguard, 48" Rangetop
PA36WLBC
– 10" Backguard, 36" Rangetop
PA30WLBC
– 10" Backguard, 30" Rangetop
PAGRIDDLE
Griddle Sits on Top of Grates Over 2 Star Burners, Non-Stick
High-Release Coating
PA12GRILLW
12" Pro Grill with Tray, (for Griddle Models), Non-Stick High-
Release Coating
PAGRIDLFW
12" Pro Griddle with Tray, (for Griddle Models), Fusion Coating
PA12GRILFW
12" Pro Grill with Tray (for Griddle Models), Fusion Coating
PA12LCVRW
12" Pro Griddle Cover (for Griddle Models)
PWOKRINGHC
Wok Ring
PAKNOBLUWR
Metallic Blue Knob Kit
PA12CHPBLK
12" Chopping Block / Cutting Board
PALPKITHW
LP Conversion Kit, Pro Rangetop Models with 4 and 6 Burners
PALPKITHW5
LP Conversion Kit, Pro Rangetop 5 Burner Model Only
PAALTKITH
High Altitude Kit, Natural Gas Pro Rangetops, 5,400 ft. to 10,200 ft.
Electrical Supply
The cord supplied with the gas ranges
having an electric griddle requires
a NEMA 5-20 receptacle. All other gas
units require a NEMA 5-15 receptacle.
Gas Requirements and Hookup
Rangetops are shipped by the factory to operate on natural gas. They
must be converted for use with propane. Verify that the type of gas
being used at the installation site matches the type of gas used by the
appliance. If the location / job site requires conversion from natural gas
to propane (LP), order the specified LP conversion kit. Field conversion
must be done by qualified service personnel only. Please refer to the LP
Conversion Instructions for further information.
Natural Gas Requirements:
• Inlet Connection:
1
/
2
" NPT internal (Minimum
3
/
4
" dia. flex line)
Supply Pressure: 6" min. to 14" max. water column (14.9 to 34.9 mb)
Manifold Pressure: 5" water column (12.5 mb)
Propane Gas Requirements:
• Inlet Connection:
1
/
2
" NPT internal (Minimum
3
/
4
" dia. flex line)
Supply Pressure: 11" min. to 14" max. water column (27.4 mb to
34.9 mb)
• Manifold Pressure: 10" water column (24.9 mb)
A manual gas shut-off valve must be installed external to the appliance,
in a location accessible from the front, for the purpose of shutting off
the gas supply. The supply line must not interfere with the back of
the unit.
High Altitude
High altitude kits are available for Thermador Pro Rangetops. Reference
the Accessory chart or Contact Customer Support for details.
Model Options
There are three sizes of Thermador Professional
®
Rangetops to choose
from — 30-inch, 36-inch and 48-inch. Models are available with various
rangetop configurations. Every model is LP convertible by ordering a
conversion kit. Be sure to reference the correct model information in this
design guide.
Installation Considerations
The information in this design guide provides key features, product
dimensions, cutouts and installation specifications. Before installing
a Thermador Professional Rangetop, be sure to verify the cutout
dimensions and electrical / gas connections. Installation instructions are
subject to change. Always consult with the installation manual included
with the product for complete details prior to the installation.
Installation Options
To ensure professional results, the cabinet and countertop openings
should be prepared by a qualified cabinet worker. The rangetop
can be installed in various positions with the front either flush or
projecting, depending on the countertop’s depth. The rangetop
is designed to hang from the countertop by its side flanges. The
countertop however, must be strong enough to support the rangetop.
It may be necessary to add a supporting cleat along each side or a
2" x 4" corner brace. Another alternative would be to construct a deck
to set the rangetop on. Consult with the installation manual packed with
the product for complete details before installing.
Above a Warming Drawer
Thermador Professional Rangetops may be installed above a
Thermador Warming Drawer to create a convenient cooking center.
A minimum 2
3
/
4
" (70 mm) clearance is required between the bottom of
the rangetop and the top of the warming drawer. Refer to the warming
drawer section for additional specifications.
Rear Clearance Requirements
30-Inch model PCG305W is suitable for 0" rear clearance to
combustible surfaces.
All other models must meet these clearances:
Thermador recommends a minimum 6" (152 mm) rear clearance to a
combustible surface. Clearances of less than 6" must be approved by
the local codes and / or by the local authority having jurisdiction.
When installing against a combustible surface, a Thermador Low
Backguard (purchased separately) is required for a 0" rear clearance to
the combustible surface.
Electrical and Gas SpeciFcations
Be sure your appliance is properly installed and grounded by a qualified
technician. Installation, electrical and gas connections, and grounding
must comply with all applicable local codes.
Thermador Professional
®
Rangetops are equipped with a 3-wire plug
and are designed to be connected to a 120V AC, 60 Hz, single-phase
power supply. A dedicated circuit breaker is required.
Model
Required Circuit Breaker
120V AC, 60Hz
PCG486WD
20 A
PCG364WD
20 A
PCG366W
15 A
PCG305W
15 A