Thermador T36BB110SS View Kitchen Design and Planning Guide - Page 78

Application, Required Blower, Optional Accessories, Required Accessories, Required Accessory

Page 78 highlights

| THERMADOR | VENTILATION | THERMADOR | VENTILATION INSTALLATION Downdraft Flexible Blower Installation - Front Exhaust With Flexible Blower Below Floor Line Example Application - Front downward application with space under floor line for duct work* - Elbow and duct work are not included 6", 8", OR 10" (152MM, 203MM, OR 254MM) ROUND REMOTE ROUGH-IN PLATE (Purchase Separately) FRONT PANEL If blower discharge is down, electrical panel must be relocated. Optional Accessories Downdraft Gas Cooktop Seal Trim Kit UCV36ST Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. Downdraft Gas Cooktop Seal Trim Kit UCV30ST Includes trim, seal, metal grill, and fasteners. Required for installations with 30" gas cooktops. EXTNCE5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. Required Blower 103/8" (264 mm) 123/4" (324 mm) 11 5/8" (295 mm) VTD600P - 600 CFM 600 CFM flexible blower can be installed as an integrated or inline blower 51/8" (130 mm) 11 5/8" (295 mm) 5" 123/4" (127 mm) (324 mm) 73/8" (187 mm) 51/4" (133 mm) measurements in inches (mm) measurements in inches (mm) Required Accessories CVTFRONT8 8" round front plate allows for front downward venting. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. *For front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. 152 Visit Thermador.com for complete specifications or text a Thermador model number to 21432 to have specs sent to your phone INSTALLATION Downdraft Flexible Blower Installation - Rear, Downward, Left or Right Side Exhaust Example Rear Exhaust Downward Exhaust Left Side Exhaust Right Side Exhaust Application - Rear, downward, left or right side exhaust options to preserve precious kitchen storage space or if ducting is more convenient for these configurations* - Requires at least 18" of clearance to fit the blower and transition - Blower must be accessible for maintenance - Elbow and duct work are not included Required Blower Required Accessory 103/8" (264 mm) 123/4" (324 mm) 11 5/8" (295 mm) 51/8" (130 mm) 5" 123/4" (127 mm) (324 mm) 11 5/8" (295 mm) 73/8" (187 mm) 51/4" (133 mm) measurements in inches (mm) measurements in inches (mm) VTD600P - 600 CFM 600 CFM flexible blower can be installed as an integrated or inline blower CVTSIDE8 8" round transition allows for left, right, rear or downward venting. Use with VTD600P blower as an inline installation, and ducting with 8" round duct connections. Optional Accessories Replacement Charcoal Filter UCVFILTER Includes 1 replacement charcoal filter for UCVRECIRC recirculation kit Downdraft Gas Cooktop Seal Trim Kit UCV36ST Includes trim, seal, metal grill, and fasteners. Required for installations with 36" gas cooktops. Recirculation Kit UCVRECIRC Includes 1 charcoal filter and 1 metal grill vent plate (blower sold separately). Use with induction / electric cooktops only Downdraft Gas Cooktop Seal Trim Kit UCV30ST Includes trim, seal, metal grill, and fasteners. Required for installations with 30" gas cooktops. EXTNCE5 This cable extends 5 ft. to move the electrical panel out of the way to offer full installation flexibility in any ducting scenario while installing the downdraft. Ability to connect two cables together to make a 10 ft. cable. *For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel can still be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical panel to downdraft. Refer to installation manual. NOTE: Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the blower and / or duct work. Refer to installation manual. 153

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131

153
152
*For front downward ducting applications, electrical panel must be remotely mounted. Optional 5' extension cable EXTNCE5 accessory is available to connect remotely placed electrical
panel to downdraft. Refer to installation manual.
Right Side Exhaust
|
THERMADOR
|
VENTILATION
|
THERMADOR
|
VENTILATION
Visit Thermador.com for complete speciFcations or text a Thermador model number to 21432 to have specs sent to your phone
Downdraft Gas Cooktop
Seal Trim Kit
UCV36ST
Includes trim, seal, metal
grill, and ±asteners. Required
±or installations with 36" gas
cooktops.
INSTALLATION
Downdraft
Application
- Front downward application with space under ²oor line ±or duct work*
- Elbow and duct work are not included
FRONT
PANEL
6", 8", OR 10” (152MM, 203MM,
OR 254MM) ROUND
REMOTE ROUGH-IN
PLATE (Purchase Separately)
If blower
discharge is
down,
electrical
panel must be
relocated.
Required Blower
VTD600P – 600 CFM
600 CFM ²exible blower can
be installed as an integrated
or inline blower
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
Optional Accessories
Required Accessories
EXTNCE5
This cable extends 5 ±t. to move the electrical panel
out o± the way to o±±er ±ull installation ²exibility in
any ducting scenario while installing the downdra±t.
Ability to connect two cables together to make a
10 ±t. cable.
CVTFRONT8
8" round ±ront plate allows
±or ±ront downward venting.
Use with VTD600P blower
as an inline installation, and
ducting with 8" round duct
connections.
Downdraft Gas Cooktop
Seal Trim Kit
UCV30ST
Includes trim, seal, metal
grill, and ±asteners. Required
±or installations with 30" gas
cooktops.
±lexible Blower Installation – ±ront Exhaust With ±lexible Blower Below ±loor Line Example
Application
-
Rear, downward, le±t or right side exhaust options to preserve precious kitchen storage space
or i± ducting is more convenient ±or these confgurations*
- Requires at least 18" o± clearance to ft the blower and transition
- Blower must be accessible ±or maintenance
- Elbow and duct work are not included
Rear Exhaust
Le±t Side Exhaust
*For only front downward ducting applications, electrical panel must be remotely mounted. Electrical panel can still
be remotely mounted in other exhaust configurations if desired. Optional 5' extension cable EXTNCE5 accessory is
available to connect remotely placed electrical panel to downdraft. Refer to installation manual.
NOTE:
Some applications may require deeper cabinets. Side and rear exhaust require at least 18" of clearance to fit the
blower and / or duct work. Refer to installation manual.
Required Accessory
Required Blower
VTD600P – 600 CFM
600 CFM ²exible blower can be installed
as an integrated or inline blower
10
3
/
8
"
(264 mm)
12
3
/
4
"
(324 mm)
12
3
/
4
"
(324 mm)
7
3
/
8
"
(187 mm)
11
5
/
8
"
(295 mm)
5
1
/
4
"
(133 mm)
5
1
/
8
"
(130 mm)
11
5
/
8
"
(295 mm)
5"
(127 mm)
measurements in inches (mm)
Optional Accessories
EXTNCE5
This cable extends 5 ±t. to move the electrical panel out o± the way to
o±±er ±ull installation ²exibility in any ducting scenario while installing the
downdra±t. Ability to connect two cables together to make a 10 ±t. cable.
Replacement Charcoal Filter
UCVFILTER
Includes 1 replacement charcoal flter
±or UCVRECIRC recirculation kit
Downdraft Gas Cooktop Seal Trim Kit
UCV36ST
Includes trim, seal, metal grill, and
±asteners. Required ±or installations
with 36" gas cooktops.
CVTSIDE8
8" round transition allows ±or le±t, right, rear
or downward venting. Use with VTD600P
blower as an inline installation, and ducting
with 8" round duct connections.
Recirculation Kit
UCVRECIRC
Includes 1 charcoal flter and
1 metal grill vent plate (blower
sold separately). Use with
induction / electric cooktops only
Downdraft Gas Cooktop Seal Trim Kit
UCV30ST
Includes trim, seal, metal grill, and
±asteners. Required ±or installations
with 30" gas cooktops.
INSTALLATION
Downdraft
±lexible Blower Installation – Rear, Downward, Left or Right Side Exhaust Example
Downward Exhaust