Toshiba Tecra M5 Maintenance Manual - Page 177
Head Cleaning
View all Toshiba Tecra M5 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 177 highlights
3.21 Head Cleaning 3.21 Head Cleaning 3 Tests and Diagnostics 3.21.1 Function Description This function cleans the heads in the FDD by executing a series of head load/seek and read operations. A cleaning kit is necessary to perform this program. 3.21.2 Operations 1. Selecting test 4 from the DIAGNOSTIC MENU and pressing Enter displays the following messages: DIAGNOSTICS - FLOPPY DISK HEAD CLEANING : VX.XX Mount cleaning disk(s) on drive(s). Press any key when ready. 2. Remove the Diagnostics Disk from the FDD, then insert the cleaning disk and press Enter. 3. When the "cleaning start" message appears, the FDD head cleaning has begun. 4. The display automatically returns to the DIAGNOSTIC MENU when the program is completed. TECRA M5 Maintenance Manual (960-542) [CONFIDENTIAL] 3-47