Yamaha CLP-240 Owner's Manual - Page 54

Panel/Status Transmit, Procedure, Initial Setup Send, Dual detune F3.2

Page 54 highlights

ENGLISH Detailed Settings - [FUNCTION] F8.6: (CLP-240)/ F7.6: (CLP-230) Panel/Status Transmit This function causes all the current CLP-240/230 panel settings (selected voice, etc.) to be transmitted via the MIDI OUT terminal. TERMINOLOGY Setup Data: Data that contains a set of panel settings for the Clavinova. Procedure 1. Set up the panel controls as desired. 2. Connect the Clavinova to a sequencer via MIDI, and set up the sequencer so it can receive the setup data. 3. Engage the Function mode and select (CLP- 240)/ (CLP-230). 4. Press the [+/YES] button to transmit the panel/status data. will appear on the LED display when the data has been successfully transmitted. NOTE See page 81 for a list of the "Panel Data Contents" transmitted by this function. NOTE Receiving the transmitted data: 1. Connect the Clavinova via MIDI to the device to which the setup data was transmitted previously. 2. Start sending the setup data from the device. The Clavinova automatically receives the setup data, which will be reflected in the panel settings. (For the data to be accepted, the Clavinova that receives the setup data should be the same model as the one that transmitted the setup data to the sequencer.) NOTE For more information on transmitting and receiving setup data via MIDI, refer to the owner's manual for the connected MIDI device. F8.7: (CLP-240)/F7.7: (CLP-230) Initial Setup Send This function lets you send the data of the panel settings to a computer. By transmitting the panel settings and recording them on the MIDI sequence recorder prior to the actual performance data, the instrument will be automatically restored to the same settings when the performance is played back. You can also use this function to change the settings of a connected tone generator to the same settings as the instrument. Procedure 1. Set up the panel controls as desired. 2. Connect the Clavinova to a sequencer via MIDI, and set up the sequencer so it can receive the setup data. 3. Engage the Function mode and select (CLP- 240)/ (CLP-230). 4. Press the [+/YES] button to transmit the panel/status data. will appear on the LED display when the data has been successfully transmitted. The following data can be sent. • Voice selection • [REVERB] type • [REVERB] depth • [EFFECT] type • [EFFECT] depth • Split point • Tuning (F1) • Dual detune (F3.2) 54 CLP-240/230 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

Detailed Settings – [FUNCTION]
CLP-240/230
Owner’s Manual
ENGLISH
54
F8.6:
(CLP-240)
/
F7.6:
(CLP-230)
Panel/Status Transmit
This function causes all the current CLP-240/230 panel
settings (selected voice, etc.) to be transmitted via the
MIDI OUT terminal.
Procedure
1.
Set up the panel controls as desired.
2.
Connect the Clavinova to a sequencer via MIDI, and
set up the sequencer so it can receive the setup data.
3.
Engage the Function mode and select
(CLP-
240)/
(CLP-230).
4.
Press the
[+/YES]
button to transmit the panel/status
data.
will appear on the LED display when the data has
been successfully transmitted.
(CLP-240)
/F7.7:
(CLP-230)
Initial Setup Send
This function lets you send the data of the panel settings
to a computer. By transmitting the panel settings and
recording them on the MIDI sequence recorder prior to
the actual performance data, the instrument will be
automatically restored to the same settings when the per-
formance is played back. You can also use this function to
change the settings of a connected tone generator to the
same settings as the instrument.
Procedure
1.
Set up the panel controls as desired.
2.
Connect the Clavinova to a sequencer via MIDI, and
set up the sequencer so it can receive the setup data.
3.
Engage the Function mode and select
(CLP-
240)/
(CLP-230).
4.
Press the
[+/YES]
button to transmit the panel/status
data.
will appear on the LED display when the data has
been successfully transmitted.
The following data can be sent.
Voice selection
[REVERB] type
[REVERB] depth
[EFFECT] type
[EFFECT] depth
Split point
Tuning (F1)
Dual detune (F3.2)
TERMINOLOGY
Setup Data:
Data that contains a set of panel settings for the Clavinova.
NOTE
See page 81 for a list of the “Panel Data Contents” transmitted
by this function.
NOTE
Receiving the transmitted data:
1.
Connect the Clavinova via MIDI to the device to which the
setup data was transmitted previously.
2.
Start sending the setup data from the device.
The Clavinova automatically receives the setup data, which will
be reflected in the panel settings.
(For the data to be accepted, the Clavinova that receives the
setup data should be the same model as the one that transmit-
ted the setup data to the sequencer.)
NOTE
For more information on transmitting and receiving setup data
via MIDI, refer to the owner’s manual for the connected MIDI
device.