Checking the regulator, 10-4. Cleaning the control box air inlet ports
View all Brother International BAS-342G manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
10-3. Checking the regulator 10. CLEANING 1. If water collects in the bottle of the regulator (1), turn the drain cock (2) in the direction of the arrow to drain the water. 2. After draining the water, tighten the drain cock (2). 4026M 10-4. Cleaning the control box air inlet ports Use a vacuum cleaner to clean the filter in the air inlet ports (2) of the control box (1) at least once a month. 4027M 10-5. Cleaning the eye guard Wipe the eye guard clean with a soft cloth. NOTE: Do not use solvents such as kerosene or thinner to clean the eye guard. 10-6. Checking the needle 4987Q Always check that the tip of the needle is not broken and also that the needle is not bent before starting sewing. 4028M 10-7. Lubrication Lubricate the sewing machine while referring to "4-18. Lubrication". BAS-342G 54