Compaq ProLiant 6500 Compaq Parallel Database Cluster Model PDC/05000 for Orac - Page 204

For a Redundant Fibre Channel Arbitrated Loop, Installing Secure Path Software for Windows

Page 204 highlights

Troubleshooting 7-17 I If the array controllers have already been set to Multibus_Failover mode, then check the integrity of the components along the unseen Fibre Channel Fabric path. Do the following: G Confirm that the Compaq KGPSA device driver was properly installed. Refer to "Installing Secure Path Software for Windows 2000" in Chapter 5, "Installation and Configuration." G Check the status LEDs on the host adapter for error indications. G Verify that the Fibre Channel cable has been properly installed between the host adapter and its Fibre Channel SAN Switch. G Check the status LEDs on the Fibre Channel SAN Switch ports for error indications. G Verify that the Fibre Channel cables have been properly installed from the Fibre Channel SAN Switch to both ports on the array controller. G Use the CLI to obtain status information about the array controller. Verify that both port 1 and port 2 on each array controller are active. For a Redundant Fibre Channel Arbitrated Loop If the cluster node cannot see all of the storagesets that are configured to the FC-AL paths, do the following: I Verify that the array controllers on the unseen path are set for Multibus_Failover mode. If an array controller has not been set to Multibus_Failover mode, then the cluster nodes will only see the storagesets that are configured to the other array controller in the storage subsystem. I If the array controllers have already been set to Multibus_Failover mode, then check the integrity of the components along the unseen FC-AL path. Do the following: G Confirm that the Compaq KGPSA device driver was properly installed. Refer to "Installing Secure Path Under Windows 2000" in Chapter 5, "Installation and Configuration." G Check the status LEDs on the host adapter for error indications. G Verify that the Fibre Channel cable has been properly installed between the host adapter and its Storage Hub. G Check the status LEDs on the Storage Hub ports for error indications.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233

Troubleshooting
7-17
If the array controllers have already been set to Multibus_Failover
mode, then check the integrity of the components along the unseen Fibre
Channel Fabric path. Do the following:
G
Confirm that the Compaq KGPSA device driver was properly
installed. Refer to
Installing Secure Path Software for Windows
2000
in Chapter 5,
Installation and Configuration.
G
Check the status LEDs on the host adapter for error indications.
G
Verify that the Fibre Channel cable has been properly installed
between the host adapter and its Fibre Channel SAN Switch.
G
Check the status LEDs on the Fibre Channel SAN Switch ports for
error indications.
G
Verify that the Fibre Channel cables have been properly installed
from the Fibre Channel SAN Switch to both ports on the array
controller.
G
Use the CLI to obtain status information about the array controller.
Verify that both port 1 and port 2 on each array controller are active.
For a Redundant Fibre Channel Arbitrated Loop
If the cluster node cannot see all of the storagesets that are configured to the
FC-AL paths, do the following:
Verify that the array controllers on the unseen path are set for
Multibus_Failover mode. If an array controller has not been set to
Multibus_Failover mode, then the cluster nodes will only see the
storagesets that are configured to the other array controller in the storage
subsystem.
If the array controllers have already been set to Multibus_Failover
mode, then check the integrity of the components along the unseen
FC-AL path. Do the following:
G
Confirm that the Compaq KGPSA device driver was properly
installed. Refer to
Installing Secure Path Under Windows 2000
in
Chapter 5,
Installation and Configuration.
G
Check the status LEDs on the host adapter for error indications.
G
Verify that the Fibre Channel cable has been properly installed
between the host adapter and its Storage Hub.
G
Check the status LEDs on the Storage Hub ports for error
indications.