Dell Force10 E600i E600i System Installation Guide - Page 30

Line Cards, Switch Fabric Modules

Page 30 highlights

www.dell.com | support.dell.com Table 7-1. RPM LEDs Status Location This is a bi-color LED. Green: operational Amber: fault detected Flashing green: booting Unlit: in secondary mode or power is off This LED is either lit blue or is unlit. It is used to locate a chassis and is turned on via the command line interface. Line Cards Line cards provide external interfaces for connections to other network devices and are hot-swappable. There are seven line card slots numbered 0 through 6. The ports are numbered from the top, starting from 0. WARNING: The line card temperatures in E600i slots 0 and 1 rise above 80 F if traffic is flowing at line rate in a fully loaded chassis. Line Card LEDs Line card LEDs are described in the documentation specific to each line card. Refer to the installation documentation that came with the card. Switch Fabric Modules SFMs plug into the backplane and carry traffic between line cards or between RPMs and a line card. A minimum of four SFMs are required in order for the E-Series system to operate properly. There is an additional slot available for a redundant SFM; if you are not operating the system with SFM redundancy, install a blank panel in the unused slot. 30 | Installing RPMs, Line Cards, and SFMs

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

30
|
Installing RPMs, Line Cards, and SFMs
www.dell.com | support.dell.com
Line Cards
Line cards provide external interfaces for connections to other network devices and are hot-swappable.
There are seven line card slots numbered 0 through 6. The ports are numbered from the top, starting from
0.
WARNING:
The line card temperatures in E600i slots 0 and 1 rise above 80 F if traffic is flowing at line rate in
a fully loaded chassis.
Line Card LEDs
Line card LEDs are described in the documentation specific to each line card. Refer to the installation
documentation that came with the card.
Switch Fabric Modules
SFMs plug into the backplane and carry traffic between line cards or between RPMs and a line card. A
minimum of four SFMs are required in order for the E-Series system to operate properly. There is an
additional slot available for a redundant SFM; if you are not operating the system with SFM redundancy,
install a blank panel in the unused slot.
Status
This is a bi-color LED.
Green: operational
Amber: fault detected
Flashing green: booting
Unlit: in secondary mode or power is off
Location
This LED is either lit blue or is unlit. It is used to locate a chassis and is turned on via the
command line interface.
Table 7-1.
RPM LEDs