Epson 2200 Service Manual - Page 152
Removing the Carriage Guide Shaft A and Carriage Unit, Removing the CR Linear Scale - printer heads
UPC - 010343841840
View all Epson 2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
EPSON Stylus PHOTO 2100/2200 A D JU S TM E N T R E Q U IR E D " When changing or removing the Carriage Guide Shaft B, make the following adjustment. • PG adjustment " After changing the following parts for new ones, always apply grease G-26 or G-56 in the specified positions. • Sub Left Adjust Parallelism Bush: Refer to Chapter 6, Figure 6-19, "Lubrication Point 21". • Sub Right Adjust Parallelism Bush: Refer to Chapter 6, Figure 6-20, "Lubrication Point 22". • Carriage Guide Shaft B: Refer to Chapter 6, Figure 6-21, "Lubrication Point 23". Revision B 4.2.9 Removing the Carriage Guide Shaft A and Carriage Unit 1. Remove the Printer Mechanism. (Refer to 4.2.1.4.) 2. Remove the Printer Head. (Refer to 4.2.7.) 3. Remove the Extension Spring 1.494 hitched on the left side of the CR Linear Scale as seen from the printer front. C A U T IO N Be fully careful when removing the Extension Spring 1.494 since pulling it more than necessary will elongate the Spring. Refer to Figure 4-72, "Removing the CR Linear Scale". CHECK P O IN T The Extension Spring 1.494 does not drop if it is removed from the left hook. Refer to Figure 4-72, "Removing the CR Linear Scale". 4. Remove the right side of the CR Linear Scale as viewed from the printer front. 5. Remove the left side of the CR Linear Scale as viewed from the printer front by turning it 90° (either upward or downward). Hook CR Linear Scale Extension Spring 1.494 Hook Hook Figure 4-72. Removing the CR Linear Scale DISASSEMBLY AND ASSEMBLY Disassembly 152