Fluke 28IIEX Fluke 28IIEx User Manual - Page 15

EX Safety Information, the Low-Pass Filter.

Page 15 highlights

• Do not work alone. • Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc. • Use only correct measurement category (CAT), voltage, and amperage rated probes, test leads, and adapters for the measurement. • Remove all probes, test leads, and accessories that are not necessary for the measurement. • Keep fingers behind the finger guards on the probes. • Limit operation to the specified measurement category, voltage, or amperage ratings. • Measure a known voltage first to make sure the Product operates correctly. • Measure for hazardous voltage without the Low-Pass Filter. • Do not apply more than the rated voltage, between the terminals or between each terminal and earth ground. • Do not touch the probes to a voltage source when the test leads are connected to the current terminals. True-rms Digital Multimeter EX Safety Information • Connect the common test lead before the live test lead and remove the live test lead before the common test lead. • Replace the batteries when the low battery indicator shows to prevent incorrect measurements. • The battery door must be closed and locked before you operate the Product. • Do not use the Product if it operates incorrectly. • Do not use and disable the Product if it is damaged. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

True-rms Digital Multimeter
EX Safety Information
5
Do not work alone.
Do not touch voltages >30 V ac rms, 42 V
ac peak, or 60 V dc.
Use only correct measurement category
(CAT), voltage, and amperage rated
probes, test leads, and adapters for the
measurement.
Remove all probes, test leads, and
accessories that are not necessary for
the measurement.
Keep fingers behind the finger guards on
the probes.
Limit operation to the specified
measurement category, voltage, or
amperage ratings.
Measure a known voltage first to make
sure the Product operates correctly.
Measure for hazardous voltage without
the Low-Pass Filter.
Do not apply more than the rated
voltage, between the terminals or
between each terminal and earth ground.
Do not touch the probes to a voltage
source when the test leads are
connected to the current terminals.
Connect the common test lead before
the live test lead and remove the live test
lead before the common test lead.
Replace the batteries when the low
battery indicator shows to prevent
incorrect measurements.
The battery door must be closed and
locked before you operate the Product.
Do not use the Product if it operates
incorrectly.
Do not use and disable the Product if it
is damaged.