Fluke 28IIEX Fluke 28IIEx User Manual - Page 61

DC Current, Capacitance, Function, Range, Resolution, Burden Voltage, Accuracy, mA dc

Page 61 highlights

True-rms Digital Multimeter Detailed Specifications DC Current Function Range Resolution Burden Voltage Accuracy μA dc 600.0 μA 6000 μA 0.1 μA 1 μA 100 μV/μA 100 μV/μA ±(0.2 % + 4) ±(0.2 % + 2) mA dc 60.00 mA 400.0 mA [1] 0.01 mA 0.1 mA 1.8 mV/mA 1.8 mV/mA ±(0.2 % + 4) ±(0.2 % + 2) A dc 6.000 A 10.00 A [2,3] 0.001 A 0.01 A 0.03 V/A 0.03 V/A ±(0.2 % + 4) ±(0.2 % + 2) [1] 400 mA continuous; 600 mA for 18 hr maximum. [2] W 10 A continuous up to 35 °C. 10 A to 20 A for 30 seconds maximum, 5 minutes off. [3] >10 A accuracy unspecified. Capacitance Range Resolution 10.00 nF 0.01 nF 100.0 nF 0.1 nF 1.000 μF 0.001 μF 10.00 μF 0.01 μF 100.0 μF 0.1 μF 9999 μF 1 μF [1] With a film capacitor or better, using the rel mode to zero residual. Accuracy ±(1.0 % + 2) [1] ±(1.0 % + 2) 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

True-rms Digital Multimeter
Detailed Specifications
51
DC Current
Function
Range
Resolution
Burden Voltage
Accuracy
μ
A dc
600.0
μ
A
0.1
μ
A
100
μ
V/
μ
A
±
(0.2 % + 4)
6000
μ
A
1
μ
A
100
μ
V/
μ
A
±
(0.2 % + 2)
mA dc
60.00 mA
0.01 mA
1.8 mV/mA
±
(0.2 % + 4)
400.0 mA
[1]
0.1 mA
1.8 mV/mA
±
(0.2 % + 2)
A dc
6.000 A
0.001 A
0.03 V/A
±
(0.2 % + 4)
10.00 A
[2,3]
0.01 A
0.03 V/A
±
(0.2 % + 2)
[1]
400 mA continuous; 600 mA for 18 hr maximum.
[2]
W
10 A continuous up to 35
°
C. <20 minutes on, 5 minutes off at 35
°
C to 55
°
C. >10 A to 20 A for 30 seconds maximum, 5 minutes
off.
[3]
>10 A accuracy unspecified.
Capacitance
Range
Resolution
Accuracy
10.00 nF
0.01 nF
±
(1.0 % + 2)
[1]
100.0 nF
0.1 nF
1.000
μ
F
0.001
μ
F
±
(1.0 % + 2)
10.00
μ
F
0.01
μ
F
100.0
μ
F
0.1
μ
F
9999
μ
F
1
μ
F
[1]
With a film capacitor or better, using the rel mode to zero residual.