Table 7. Functions and Trigger Levels for Frequency Measurements, Function, Range, Approximate
View all Fluke 28IIEX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
28 II Ex Users Manual Function Table 7. Functions and Trigger Levels for Frequency Measurements Range Approximate Trigger Level Typical Application 6 V, 60 V, ±5 % of scale Most signals. 600 V, 1000 V 600 mV ±30 mV High-frequency 5 V logic signals. (The dc-coupling of the L function can attenuate high-frequency logic signals, reducing their amplitude enough to interfere with triggering.) 600 mV 40 mV Refer to the measurement guidelines given before this table. V 6 V 1.7 V 5 V logic signals (TTL). V 60 V 4 V Automotive switching signals. V 600 V 40 V Refer to the measurement guidelines given before this table. V 1000 V 100 V Frequency counter characteristics are not available or specified for these functions. μA All ranges ±5 % of scale 600 μA, 6000 μA 30 μA , 300 μA AC current signals. Refer to the measurement guidelines given before this table. A 60 mA, 400 mA 3.0 mA , 30 mA 6 A, 10 A .30 A, 3.0 A 32