Fluke 8845A FE 8845A & 8846A Users Manual - Page 23
A Accuracy, Additional Low Frequency Errors, Resistance - specification
View all Fluke 8845A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
1 Introduction and Specifications Electrical Specifications 8845A Accuracy Accuracy is given as ± (% measurement + % of range) Range Frequency (Hz) 24 Hour (23 ± 1 °C) 100 mV 3 - 5 Hz 1.0 + 0.03 5 - 10 Hz 0.35 + 0.03 10 Hz - 20 kHz 0.04 + 0.03 20 - 50 kHz 0.1 + 0.05 50 - 100 kHz 100 - 300 kHz[1] 0.55 + 0.08 4.0 + 0.50 1 V 3 - 5 Hz 1.0 + 0.02 5 - 10 Hz 0.35 + 0.02 10 Hz - 20 kHz 0.04 + 0.02 20 - 50 kHz 0.1 + 0.04 50 - 100 kHz 100 - 300 kHz[1] 0.55 + 0.08 4.0 + 0.50 10 V 3 - 5 Hz 1.0 + 0.02 5 - 10 Hz 0.35 + 0.02 10 Hz - 20 kHz 0.04 + 0.02 20 - 50 kHz 0.1 + 0.04 50 - 100 kHz 100 - 300 kHz[1] 0.55 + 0.08 4.0 + 0.50 100 V 3 - 5 Hz 1.0 + 0.02 5 - 10 Hz 0.35 + 0.02 10 Hz - 20 kHz 0.04 + 0.02 20 - 50 kHz 0.1 + 0.04 50 - 100 kHz 100 - 300 kHz[1] 0.55 + 0.08 4.0 + 0.50 750 V 3 -- 5 Hz 1.0 + 0.02 5 - 10 Hz 0.35 + 0.02 10 Hz - 20 kHz 0.04 + 0.02 20 - 50 kHz 50 - 100 kHz [2] 100 - 300 kHz[1] [2] 0.1 + 0.04 0.55 + 0.08 4.0 + 0.5 [1] Typically 30 % reading error at 1 MHz [2] 750 Volt range is limited to 8 X 107 volt-Hertz 90 Days (23 ± 5 °C) 1.0 + 0.04 0.35 + 0.04 0.05 + 0.04 0.11 + 0.05 0.6 + 0.08 4.0 + 0.50 1.0 + 0.03 0.35 + 0.03 0.05 + 0.03 0.11 + 0.05 0.6 + 0.08 4.0 + 0.50 1.0 + 0.03 0.35 + 0.03 0.05 + 0.03 0.11 + 0.05 0.6 + 0.08 4.0 + 0.50 1.0 + 0.03 0.35 + 0.03 0.05 + 0.03 0.11 + 0.05 0.6 + 0.08 4.0 + 0.50 1.0 + 0.03 0.35 + 0.03 0.05 + 0.03 0.11 + 0.05 0.6 + 0.08 4.0 + 0.5 1 Year (23 ± 5 °C) 1.0 + 0.04 0.35 + 0.04 0.06 + 0.04 0.12 + 0.05 0.6 + 0.08 4.0 + 0.50 1.0 + 0.03 0.35 + 0.03 0.06 + 0.03 0.12 + 0.05 0.6 + 0.08 4.0 + 0.50 1.0 + 0.03 0.35 + 0.03 0.06 + 0.03 0.12 + 0.05 0.6 + 0.08 4.0 + 0.50 1.0 + 0.03 0.35 + 0.03 0.06 + 0.03 0.12 + 0.05 0.6 + 0.08 4.0 + 0.50 1.0 + 0.03 0.35 + 0.03 0.06 + 0.03 0.12 + 0.05 0.6 + 0.08 4.0 + 0.5 Temperature Coefficient/ °C Outside 18 to 28 °C 0.10 + 0.004 0.035 + 0.004 0.005 + 0.004 0.011 + 0.005 0.06 + 0.008 0.2 + 0.02 0.1 + 0.003 0.035 + 0.003 0.005 + 0.003 0.011 + 0.005 0.06 + 0.008 0.2 + 0.02 0.1 + 0.003 0.035 + 0.003 0.005 + 0.003 0.011 + 0.005 0.06 + 0.008 0.2 + 0.02 0.1 + 0.003 0.035 + 0.003 0.005 + 0.003 0.011 + 0.005 0.06 + 0.008 0.2 + 0.02 0.1 + 0.003 0.035 + 0.003 0.005 + 0.003 0.011 + 0.005 0.06 + 0.008 0.2 + 0.02 Additional Low Frequency Errors Error is stated as % of reading. Frequency 3HZ (slow) AC Filter 20HZ (medium) 10 - 20 Hz 0 0.25 20 - 40 Hz 0 0.02 40 - 100 Hz 0 0.01 100 - 200 Hz 0 0 200 Hz - 1 kHz 0 0 > 1 kHz 0 0 200HZ (fast) - - 0.55 0.2 0.02 0 Resistance Specifications are for 4-wire resistance function, 2 x 4-wire resistance, or 2-wire resistance with zero. If zero is not used, add 0.2 Ω for 2-wire resistance plus lead resistance, and add 20 mΩ for 2 x 4-wire resistance function. Measurement Method Current source referenced to LO input. 1-13