Haier AB122MCERA Operation Manual - Page 33
Ocicicie, Giccide
View all Haier AB122MCERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Electrical Wiring (Signal Wiring Draw n) ABC ABC outdoor1 P Q outdoor 2 ABC outdoor 3 indoor 1 °Pm ABC indoor 6 P Q indoor 2 ABC indoor 7 P communication wire with polarity indoor 3 Kw° ABC indoor 4 P Q ABC ABC indoor8 P indoor 9 P control wire for wired controller with polarity ABC indoor 5 P A B C wired controller ABC indoor 10 P wired controller wired controller wired controller wired controller wired controller indoor 11 indoor 12 OCICICIE FUEN / wired controller 0000 (WM indoor 13 indoor 14 indoor 15 wired l• - GICCIDE tION wired controller I A BC 1m1:1i1n211:113 B C wired controller wired controller ABC indoor 16 P ABC ABC ABC indoor17 P indoor 18 P indoor 19 P indoor 20 wired controller wired controller wired controller wired controller 000 wired wired controller controller Outdoor units are of parallel connection via three lines with polarity. The main unit, central control and all indoor units are of parallel connection via two lines without polarity. There are three connecting ways between line control and indoor units: A. One line control controls multiple units, i.e. 2-16 indoor units, as shown in the above figure, (1-5 indoor units). The indoor unit 5 is the line-controlled main unit and others are the ine-controlled sub units. The remoter control and the main unit (directly connected to the indoor unit of line control) are connected via three lines with polarity. Other indoor units and the main unit are connected via two lines with polarity.SW01 on the main unit of line control is set to 0 while SW01 on other sub units of line control are set to 1, 2, 3 and so on in turn. (Please refer to the code setting A at page 33) B. One line control controls one indoor unit, as shown in the above figure(indoor unit 6-19). The indoor unit and the line control are connected via three lines with polarity. C. Two line controls control one indoor unit, as shown in the figure (indoor unit 20). Either of the line controls can be set to be the master line control while the other is set to be the auxiliary line control. The master line control and indoor units, and the master and auxiliary line controls are connected via three lines with polarity. When the indoor units are controlled by the remote control, switch over the modes by Switching Mode of Line-Controlled Main Unit/ Line-Controlled Sub Units/ Remote-Controlled Types. The signal terminals needn't to be equipped with wires and connected to the line control. 31