Haier AB122MCERA Operation Manual - Page 37
Functions, Wired, Controller
View all Haier AB122MCERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Functions of Wired Controller (Operation of Wired/Remote Controllers D 0 Initialization process of line control: During the initialization of line control after powered on, [8888]-[888]-[88]-[8] for the wired controllers and LED flash for about 30 seconds. At this time, all buttons are disabled. 0 Descriptions of other components and operating methods refer to the related operating guide. 0 Special functions of wired control: A Setting of central control address of indoor units: When indoor unit code setting allows line control to set the address, continually press "Resetting Filtering Screen" for 10 seconds to enter into the mode of setting the central control addresses, and select the unit No. of the group by "Time +/-" button. Indication of temperature displays: [Central Control Address]+XX: Press "Temp. +/-" button. )O( ranges from 0-7F with the initial value of 00. After finishing the setting, press "Setting" button to save the setting and quit. By pressing other buttons or without pressing within 15 seconds, it will automatically quit and keep the last setting. B Setting of communication address between indoor units and outdoor units: When indoor unit code setting allows line control to set the address, continually press "Resetting Filtering Screen" for 5 seconds to enter into the mode of setting the communication addresses, and select the unit No. of the group by "Time +/-" button. Indication of temperature displays: [System Address]+XX: Press "Temp. +/-" button. )O( ranges from 0-3F with the initial value of 00. after finishing the setting, press "Setting" button to save the setting and quit. By pressing other buttons or without pressing within 15 seconds, it will automatically quit and keep the last setting. C Inquiry of fault records of indoor units: In the state of startup or shutdown, press "CHECK" button to go into the mode of inquiring faults of all indoor units in this group. The temperature zone indicates "CHECK" and "Unit No.", which shows the unit number with the actual connection in sequence in the decimal system. Meanwhile, the time zone indicates the code of the current fault and the previous fault of the responding machine in the format of [XX:YY], in which, )O( refers to the code of the current fault (if normal, it shows "- -") and YY refers to the code of the previous fault. The indication of fault code of each machine lasts 3 seconds. After the indication of the whole group, it automatically quit. Removing abnormal states & clearing fault records: D Under normal conditions, continually press "CHECK" button for 5 seconds to clear fault records. Inquiring running state of indoor units of the group: E Under normal condition, press "Setting" button for 5 seconds until the temperature zone on the liquid crystal screen shows [XX], referring to the unit number of indoor units and select unit, and select unit number by "Temp. +/-" button. The time zone displays [YZZZ], in which, Y refers to the data type and ZZZ to the responding data. Select the data type by "Time +/-" button. Y ZZZ System A Temperature of indoor unit transducer TA Actual value, decimal system B Temperature of indoor unit transducer TC1 Actual value, decimal system C Temperature of indoor unit transducer TC2 Actual value, decimal system D PMV step of indoor units Actual value/2. decimal system(e.g. indication of 50 with actual step of 100) E Communication address between indoor/outdoor units Actual value, sexadecimal system F Central address Actual value, sexadecimal system Under the inquiring state, press "CHECK" button to quit the inquiring state and return to the normal operating state. 35