Haier AB122MCERA Operation Manual - Page 35
Haier AB122MCERA Manual
View all Haier AB122MCERA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
Electrical Wiring 0 Indoor Units PCB A. With the indoor units controlled by the line control in groups, the address setting of indoor units: SW01 [1]-[4] X The setting of SW01 is performed by installation personnel during installation. X Switch SW01 of the matching indoor unit to "0" in one line control to one unit, double line controls to one unit and remote controlling conditions. 1 SW01 2 3 4 wired controller address 0 000 0 0 001 1 0 010 2 0 011 3 Position of SW01 Main Unit Position of SW01 Sub Unit 0 10 0 4 0 1-15 (The dialing codes of sub units in the same 0 1 0 1 5 group should be different) 1 1 0 0 12 B. The central control address setting of indoor units: SW02 X When controlled by line control in groups, the main unit needs to be set while it is unnecessary to set the sub units. 1 1 0 1 13 1 1 1 0 14 1 1 1 1 15 X The setting of SW02 can be done by installation personnel during installation. SW02 Switching Description [1] [2] [3] [4] [5] [6] [7] [8] -- 101 101 101 101 I 0 I 101 10I Central control address = 1 -- 0 0 0 0 0 0 1 Central control address = 2 ---- ---- -- 1 1 1 1 1 1 0 Central control address = 127 -- 1 1 1 1 1 1 1 Central control address = 128 o Allowed wire controller address setting 1 Forbidden wire controller address setting C. Communication Address Setting between Indoor Units and Outdoor Units: SW03 X The setting of SW03 can be done by installation personnel during installation. SW03 Switching Description [1] [2] [3] [4] [5] [6] [7] [8] -- -- 10 I 10 I 10 I 10 I 10 I 10 I Communication address of indoor units = 1 -- -- 0 0 0 0 0 1 Communication address of indoor units = 2 ---- ---- -- -- 1 1 1 1 1 0 Communication address of indoor units = 63 -- -- 1 1 1 1 1 1 Communication address of indoor units = 64 -- 0 Allowed wire controller address setting -- 1 Forbidden wire controller address setting 0 Automatic address setting 1 Manual address setting • There are 1 ways of setting communication addresses between indoor units and outdoor units: A. Manual: first, set SW03-[1] to "1", and then set SW03-[8]-[3] according to requirements. B. Take one of the three ways while only one way is valid at the same time. The highest priority level is the Line Control way. C. Line/Remote Control Option: set SW08-[6]. X The setting of SW08-[6] can be done by installation personnel during installation. Status of SW08-[5] Controlling Method ON Room card available OFF unavailable 33