- HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 1
HP StorageWorks Fabric OS 6.4.0c Release Notes Part Number: 5697-0703 First edition: September 2010 - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 2
Legal and notice information © Copyright 2010 Hewlett-Packard Development Company, L.P. © Copyright 2010 Brocade Communications Systems, Incorporated - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 3
Version 6.4.0c NOTE: This software conforms to the Fibre Channel (FC) standards and accepted engineering practices and procedures. Description Fabric OS 6.4.0 introduced support for the following new hardware. This support is carried forward with 6.4.0c: • HP StorageWorks DC SAN Director 64-Port 8Gb - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 4
Fabric OS and later installed, the following default characteristics of the switch were revised: • Virtual fabrics are enabled by default. See the Fabric OS Administrator's Guide for 6.4.0 for in- formation on the configuration of VF. The following switches support virtual fabrics: • DC SAN Backbone - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 5
a DC SAN Backbone and DC04 SAN Director chassis from 2 to 4. • Troubleshooting enhancements - New tperf diagnostic CLI-Fabric OS 6.4.0 added support for a new FCIP diagnostic CLI tperf used to determine tunnel characteristics, generate High, Medium, HP StorageWorks Fabric OS 6.4.0c Release Notes 5 - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 6
Troubleshooting enhancements • Frame Monitoring-This feature enhances configuration of existing filter based monitors supported Brocade issued certificates were supported. will be deprecated in future releases. • Sysmonitor CLI has been enhanced to support The following software enhancements were made - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 7
support guides or other materials but will will be available in separate documentation. • Support supported only receive (Rx) timeout counters. See the Fabric Watch Administrator's Guide failure. • Fabric OS 6.4.0 added support for the Lossless DLS with DPS DLS feature was supported only for Port - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 8
supported in both Access Gateway and Switch modes. Virtual fabrics enhancements Fabric OS 6.4.0 added support Enterprise editions. Option to install only SMIS without DCFM client capabilities is also supported. Optionally licensed software into one logical Services)-For the HP StorageWorks B-series - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 9
must have the ICL license installed in order to enable ICL virtual machines by extending virtual channels to the server infrastructure. Application-specific traffic flows can be configured, prioritized, and optimized throughout the data center infrastructure. This license is not supported on the HP - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 10
support At the time of this document release, HP does not support temporary licenses or Universal Temporary Licenses. Standards compliance This software • IEEE 802.1Q, VLAN Tagging • IEEE 802.1p, Class of Service Prioritization and Tagging • IEEE 802.1v, VLAN Classification by Protocol and Port - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 11
Working Group) • FC-BB-5, FCoE (Rev. 2.0.0) New hardware support Fabric OS 6.4.0 introduced support for series products and is required for the 64 port blade. Supported product models Fabric OS 6.4.0c is supported on the following product models: • HP StorageWorks 4/32 SAN Switch (Brocade 4100) • HP - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 12
Gateway connectivity is supported by the switches listed in this section and also by the following B-series switches: • HP StorageWorks 4/16 SAN Switch (Brocade 200e) • HP StorageWorks 4/32 SAN Switch • HP StorageWorks 4/32B SAN Switch • HP StorageWorks 4/64 SAN Switch • HP StorageWorks 4/256 SAN - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 13
and virtual) attached to it, while allowing easy SAN connectivity. The edge fabric switch provides all fabric services, while Guide, available on http:// www.hp.com/go/san. Access Gateway support in non-Brocade fabrics In addition to being supported in Brocade fabrics, Access Gateway is supported - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 14
problems may arise when configuring settings through these older products. NOTE: Do not configure zoning through a switch operating with Fabric OS 3.x in a fabric that has products operating with later versions of Fabric OS. Prerequisites Table 1 lists the supported Fabric OS firmware versions. HP - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 15
StorageWorks 16 Port 4Gb Blade (FC4-16) HP StorageWorks 32 Port 4Gb Blade (FC4-32) HP StorageWorks 48 Port 4Gb Blade (FC4-48) HP StorageWorks 400 MP Router8 HP StorageWorks 4/32 SAN Switch HP StorageWorks 4/32B SAN Switch HP StorageWorks B-series iSCSI Director Blade (FC4-16IP) 6.2.1b Brocade 4Gb - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 16
with Fabric OS 6.4, but cannot be directly attached via an E_Port to any products running Fabric OS 6.4. For information about HP support of interoperable fabrics, see HP StorageWorks Merging Fabrics Based on M-series and B-series Fibre Channel Switches Application Notes, available at http://www - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 17
supported for interoperability with Fabric OS 6.3. For information about HP support of interoperable fabrics, see HP StorageWorks Merging Fabrics Based on M-series and B-series installed if they are used only for FC FastWrite or FCIP without routing. HP StorageWorks Fabric OS 6.4.0c Release Notes - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 18
of two blades per director. The DC SAN Director Switch 10/24 FCoE Blade can be installed in the same chassis only with FC8-xx (except FC8-64) and/or FC10-6 blades. It is not supported in the chassis with any other blades. Power supply requirements for Director blades Table 4 lists power - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 19
FS8-18 blades, (2+2) 220 VAC power supplies are required for redundancy. For one or two FS8-18 blades, only two power supplies are required for redundancy. scalability support, see the HP StorageWorks SAN Design Reference Guide, available at: http://www.hp.com/go/sandesignguide HP StorageWorks - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 20
product and the successor to existing B-series management products, including HP StorageWorks Fabric Manager (FM) and Enterprise Fabric Connectivity Manager (EFCM). DCFM is available in three versions (see the DCFM release notes for full support details): • DCFM Professional-An application bundled - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 21
the earliest versions of software supported in this release, that is, the earliest supported software versions that interoperate. HP recommends using the latest software versions to get the greatest benefit from the SAN. When using the Virtual Fabrics (VF) feature, HP recommends that all switches - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 22
one or more DC SAN Director Switch 10/24 FCoE Blades. NOTE: HP may not support all of these switches in this mode. For information about support in interopmodes 2 and 3, see HP StorageWorks Merging Fabrics Based on M-Series and B-Series routing) Yes Yes Virtual Channels (VC RDY) Yes7 Yes7 22 - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 23
Fabrics Alias Server Platform Service FCIP (VE_Ports) IPFC (IP over FC) M-EOS ALPA 0x13 configuration VE_Port to VEX_Port Integrated Routing4 Domain Offset Support 239 Domain Support (available on Mi10K only Yes Yes12 Yes Yes Yes Yes Yes N/A Yes HP StorageWorks Fabric OS 6.4.0c Release Notes 23 - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 24
0c is allowed only from Fabric OS 6.3.x. The policy to support one-level migration only, which began with Fabric OS 6.0.0, provides more allowing for thorough testing and verification of supported migration paths. If you are migrating from Fabric OS 6.1.x, HP recommends that you use Fabric OS 6.2.2c - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 25
the fixes and new features. Upgrading to Fabric OS 6.4.0c is allowed only from Fabric OS 6.3.x. For more guidelines, see "Update recommendation" on page 5. To access the latest Fabric OS 6.4.0c firmware, configuration files, and MIB files, see the HP website: http://www.hp.com/support/downloads On - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 26
download is complete, enter the firmwareDownloadStatus command on the switch, verify that the process is complete, and then proceed to the next switch. Scalability For details on supported scalability, see the HP StorageWorks SAN Design Reference Guide, available on the HP website: http://www.hp - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 27
all six GE ports. HP recommends software compression for lowthroughput links and supports throughput up to 2 Gb firmware activation on Fabric OS 6.4.x will disrupt I/O traffic on FCIP TCP virtual connections are removed. For more details, see the Brocade Fabric OS FCIP Administrator's Guide for - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 28
24 FCoE Blade if the CNA interface is toggled repeatedly over time. This issue is related to the CNA; rebooting the CNA restores connectivity. • Although Switch 10/24 FCoE Blade support the configuration of multiple CEE maps, HP recommends that you use only one CEE map on all interfaces connected - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 29
one of the login groups to satisfy the requirement to keep the login group name unique in the fabric-wide configuration. • Ethernet switch services config enabled will cause a support FCoE functionality when installed in Virtual Fabrics • On VF-capable platforms, the VF feature (initially supported - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 30
6.0 or later must be installed on all products in order to with flow-based QoS. Major problems occur if previous-generation 2Gb downloaded from the following HP website: http://www.hp.com/support/manuals Under storage, select Storage networking, and then select the appropriate switch under B-series - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 31
shipping with Fabric OS 6.3.1a or later or units running Fabric OS 6.3.x that are reset to a default configuration. Use fcrbcast --enable to explicitly enable IPFC over FCR. Broadcast sharing • VEX edge to VEX edge device sharing is not supported. HP StorageWorks Fabric OS 6.4.0c Release Notes 31 - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 32
one M-series switch. Fabric OS switches in interopmode 3 (McDATA Open Fabric Mode) do not support configuration of zoning without an M-series switch in the fabric. When migrating from M-series to B-series switches, all B-series , issue the Switch will not VF mode to install new certificates. FICON - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 33
directors/switches but do not load balance in a FICON configuration. • For HP StorageWorks 8/40 or 8/80 SAN Switches with factory installed Fabric OS 6.3.1a that will be configured in FICON environments, there is an issue with PID assignment. See "Miscellaneous" on page 38 for further details on - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 34
portMirror command in the Command Reference Guide for more information on mirror port configuration and requirements. 10G interoperability 10G interoperability between the HP StorageWorks SAN Director 6 Port 10Gb FC Blade and McDATA blades is not supported due to a hardware limitation. However, the - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 35
Fabric Watch Administrator's Guide for v6.4.0. a zone alias will be stored as ports are disabled on only one side of an ICL support for frame-based trunking with Extended Fabrics, Fabric OS 6.2.x and later has been enhanced to support interoperability with these distance extension devices. HP - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 36
resets. The Adaptive Networking SID/DID Traffic Prioritization QoS feature is not supported on Extended Fabrics E_Ports when IDLE primitives are configured on these ports. In this mode, only data virtual words, which works for 1Gb, Manual supporting Fabric OS v6.4 for details on the - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 37
be changed. 6.1.2x and 6.2.0c and later (HP did not support 6.1.2c or 6.2.0c) Added the ability to installed in the factory, the default setting for all internal and external ports is mode 0. The setting can be changed by the user on a port-by-port basis and will be persistent. Upgrading to one - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 38
HP BladeSystem c-Class Implemented support for modes 2 and 3 as described below. The default setting for all ports is mode 0, regardless of what Fabric OS version was previously installed. However, ports previously set to mode 1 by the user via the portcfg- fillword command are persistent, and will - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 39
error message would be issued. Fabric OS 6.3.1b and later now reclassifies these messages as warnings, rather than critical errors. • HP recommends that no multiple encryption engines (encryption blades) installed in a director-class chassis when more than one encryption engine has access to the - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 40
issuing a commit operation. Previous to Fabric OS 6.3.1a, if the data encryption group (Encryption Group) became incomplete (one or more members became inaccessible due to network problems modifications to the CTC or LUNs on an HP Encryption Switch or HP Encryption Blade, make sure that there are no - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 41
encryption, HP Encryption Switch only one Ethernet of fresh install run problems. • The HTTP server should be listening to port 9443. SKM is supported only when configured to port 9443. • Configuring a Brocade group on SKM: As described in the Fabric OS Encryption Administrator's Guide - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 42
, issue cryptocfg supported. See the Encryption Admin Guide for configuration information. If you are using dual SKMs on Encryption SAN Switch/Encryption FC blade Encryption Group, these SKM Appliances must be clustered. Failure to cluster results in key creation failure. Otherwise, register only one - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 43
Windows and Veritas Volume Manager/Veritas Dynamic Multipathing, when LUN sizes less than 400 MB are presented to the Encryption SAN Switch for encryption, a host panic may occur; this configuration is not supported for Fabric OS 6.3.x. • HCL from Fabric OS 6.2.x to 6.3.1x is supported use one of - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 44
keys. In other words, adding new targets or LUNs to the encryption path will not work until both the SKM nodes are available. However, there will not be any issue for retrieving keys or using the existing setup as long as one SKM node is available. The encryption switch makes sure that any new KEY - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 45
add new device, bounce device ports could trigger route problem, causing host to not see the device. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Disable SMI agents. Multiple FCR masters in edge fabrics after ISL issues in the backbone. Fixed in Fabric OS 6.4.0 CP rolling reboot on 24000 - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 46
C2-5830 message followed by kernel panic on blade driver: ASSERT - Failed expression: port0 && oid_is_valid(port0). Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Avoid HA Failover on a chassis with 10/24 FCoE blades installed. 400 multiprotocol router panicked while upgrading the peer 400 - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 47
The degree to which the user will be locked out would depend on how the LDAP environment was setup. In VF mode, non-Disruptive firmware download on an HP StorageWorks 8/40 switch with more than 1MB zone DB across multiple logical switches, may cause disruption. Fixed in Fabric OS 6.4.0 Workaround - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 48
Fixed Virtual Fabric configurations. Traffic across VE tunnel is not resumed after portdisable and portenable the GE port. Fixed Fixed Fixed Fixed Fixed in Fabric OS 6.4.0 High CPU load from DCFM performing "supportsave" causes ports to Fixed in Fabric OS 6.4.0 go offline with laser FLT/ link reset - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 49
64 kernel message buffer being used up in virtual fabric with logical ISL configured. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade install, configdownload does not download some of the Fixed in Fabric OS 6.4.0 FCoE settings in Fabric OS 6.3.0. This issue pertains to the factory only and will - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 50
injection on the port. Fabric OS will not route BLS frames to cascaded CUP. IFCCs seen for Fixed in Fabric OS 6.4.0 timeouts when FICON Fixed in Fabric OS 6.4.0 disruptive firmware download. Executing configdownload on HP StorageWorks DC SAN director 10/24 FCoE blade when configured in Virtual - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 51
for CUP Port Connectivity. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Access the edit window for the file and Fixed in Fabric OS 6.4.0 After 8Gb blade fault with HP StorageWorks 4/256 SAN Director, DC SAN Director or DC04 SAN Director, port was taken offline at asic level, but offline - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 52
0 - 3 of multiprotocol router blade or 400 MP router. Error message occurs stating NPIV not supported on Fabric port, although NPIV is enabled on the 1606 ports. No problem logging into ports 4 - 31. Fixed in Fabric OS 6.4.0 Port to port connectivity failures due to slow RNID processing on 4Gb - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 53
of the router; or slotpower off/on of router blade, or Power On Reset the chassis. After a target port bounce, the FC FastWrite host cannot recognize the Fixed in Fabric OS 6.4.0 target due to cam setup problem on the backend port used by FC FastWrite. WWN Based PID Assignment assigning wrong - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 54
work for NPIV/loop ports when one device tries to get another devices information on the same port using name based queries (GID_PN, GID_NN), which could lead to device communication failures. Fixed in Fabric OS 6.4.0 Host failed to discover tapes due to a VI/VT (Virtual Initiator/Virtual Target - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 55
and CUP appears to not be working. User did hafailover one of the switches, and error messages stopped. Fixed in Fabric OS 6.4.0 After removal and insertion of the HP StorageWorks Encryption blade, the lscfg --show command will show ASIC not ready errors and FW5002 will be observed in the internal - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 56
you will not be notified about temperature over threshold events. Fixed in Fabric OS 6.4.0 In a remote corner case, an IPC failure message appears on one of the nodes when using the cryptocfg --show -groupmember -all command. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Issue "cryptocfg - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 57
a diag command is inoperative. Log function works fine with Fabric OS 6.1.0. After removing a blade other than 10/24 FCoE blade from the chassis, Fixed in Fabric OS 6.4.0 CEE tab disappears in the Portadmin GUI Window. Downloading a fabric watch configuration using configdownload after upgrading - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 58
summary Solution Software verify error detected appears on console during upgrade to Fixed in Fabric OS 6.4.0 6.3.0 from RC builds on HP StorageWorks 8/80 SAN Switch. This issue will not be seen in the field. Display of the CP disappeared from WebTools when the blade experi- Fixed in Fabric - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 59
light is shown, but port is online and working. GbE ports on HP StorageWorks Extension SAN Switch or Multiprotocol Extension Blade will continually showail No_Sync status if non-B-series SFP was inserted and then replaced with B-series SFP. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Use - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 60
issued. Incorrect port shows I/O traffic on 2408 FCoE Switches and 10/24 Fixed in FCoE Blades. Fixed in Fabric OS 6.4.0 During reboot, HP StorageWorks D2D Backup System device sends the Fixed the rekey daemon causes an HP Storage- Fixed in Fabric OS 6.4.0 Works Encryption SAN Switch fault during - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 61
Fixed in Fabric OS 6.4.0 When port 254 is used in directors in non-FICON setup, after multiple Fixed the chassis appears. Fixed in Fabric OS 6.4.0 During power off/on switch test with HP StorageWorks DC SAN port, and AG will respond to these frames with ACC rather than drop. Fixed in Fabric OS - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 62
errors. When running a third-party host scan, the http daemon (weblinker.fcg) Fixed in Fabric OS 6.4.0 terminates and restarts several times, causing a temporary management service interruption. "Bad zone config" message is given in the status message window of the zone admin module, when user - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 63
. This will complete the process successfully. WebTools zone admin page may not automatically refresh, when a zoning configuration is enabled from McDATA switch. Fixed in Fabric OS 6.4.0 In WebTools CEE tab configuration changes are not logged in the log Fixed in Fabric OS 6.4.0 window. HP - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 64
. 2. Both switches will merge and generation number will be rectified (made consistent) with configuration. 3. Bring the ISL back up and merge will go through. Or The SNMP queries for the port speeds of FCoE ports actually return 0 Fixed in Fabric OS 6.4.0 GB/sec. You may see bmd assert and failover - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 65
OS 6.4.0 SAN switch GbE ports. License Consumed Slots is zero after config download for some of the Fixed in Fabric OS 6.4.0 slot based licenses. Zone changes of Fabric Class areas in fwconfigure does not work. Fixed in Fabric OS 6.4.0 configdownload of 6.2.0 config file with max tested CTCs - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 66
in a stress to fail test - One of the LISLs in a logical switch may get disabled due to zone conflict. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Issue "lfcfg --lislenable" to recover the disabled lisl. On 4/64 SAN switch, when HCL firmware download from 6.3 to 6.2.0g, observe - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 67
will logout of the FCF after about 20 seconds. Fixed Fixed in Fabric OS 6.4.0 Fabric OS 6.4.0a fixes Fixed 's Fixed in Fixed in a logical Fixed in Fabric specific virtual virtual initiator associated with the internal port fails to appear in name server. Fixed IM2/IM3 fabrics. Fixed in Fabric OS - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 68
when FMS mode is enabled and port is moved between different logical switches from the DCFM. Fixed in Fabric OS 6.4.0a In WebTools, Name server tab unable to export name server data SAN switches over 1G GE port. Same issue applies to multiprotocol extension blades. Fixed in Fabric OS 6.4.0a 68 - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 69
(HAC) is set for manual failback. This defect is not seen if there are multiple paths through the fabric, so loss of one switch does not create a temporary loss of path. Fixed in Fabric OS 6.4.0b. When F_Port trunking is activated and after the master trunk goes offline, the switch adds the new - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 70
to get impacted over VEX. Addition of end-to-end monitors through DCFM or CLI will fail after an HA failover, if the monitors were installed on the switch before the failover on switches with Condor2 ASICs. Fixed in Fabric OS 6.4.0b. Workaround prior to upgrade: Clear all existing end-to-end - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 71
SAN Switch or Multiprotocol Extension Blade. Tape devices are intermittently detected as offline by the host during backup. Seen in setup where some physical initiators do not register as FC4 type device and others do. Fixed in Fabric OS 6.4.0b. Unable to disable default zone from Mi10k in - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 72
As a result, the active and backup CP end up out of synch. Fixed in Fabric OS 6.4.0c. Workaround prior to upgrade: Reboot the standby CP manually. During tape reads, dropping the first and middle data frames results in Fixed in Fabric OS 6.4.0c. a connection timeout error, while dropping the last - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 73
tunnel. If issues are occurring with FICON emulation and ESCON devices, disable FICON emulation. In the case of the failed tape job, resubmit it. Configdownload fails on 2408 FCoE converged network switch if no FCoE license installed. Fixed in Fabric OS 6.4.0c. Effective date September 2010 HP - HP 4400 | HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 74
74
HP StorageWorks Fabric OS 6.4.0c
Release Notes
Part Number: 5697-0703
First edition: September 2010