HP 4400 HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 25

Firmware migration considerations, Firmware upgrade instructions

Page 25 highlights

The 2408 FCoE Converged Network Switch does not support nondisruptive HCLs. As a result, any firmware upgrades are disruptive to the I/O through the switch. Similarly, a code load of DC SAN Director or DC04 SAN Director with one or more DC SAN 10/24 FCoE blades disrupts traffic through the blade. If there are multiple node encryption groups (EGs) in a fabric, complete the firmware download on one node at a time before downloading on another node. Disable the ports in DC SAN Backbone Director Logical Switches that use 10 bit addressing mode that have 8 bit areas in the range 0x70-0x8F before upgrading to Fabric OS 6.4.x. Otherwise firmware upgrade fails with an error message. This step is necessary even if you do not plan to use FC8-64 blades after performing firmware upgrade to Fabric OS 6.4.0. However, if areas 0x70-0x8F are not in use, this step is not necessary. Use portAddress CLI to find out the areas in use within a Logical Switch. If Bottleneck detection feature is currently enabled on the switch running Fabric OS 6.3.x, you must disable it before upgrading to Fabric OS 6.4.x; otherwise, frame drops may occur due to increased Hot Code Load (HCL) time. 1606 Extension SAN Switch and DC SAN Director Switch Multiprotocol Extension blade must be power cycled after upgrading from Fabric OS 6.3 to Fabric OS 6.4. This is necessary to load the new FPGA image that enables IPv6 capability for FCIP links to the switch and the blade. This step is mandatory even if IPv6 is not used on the FCIP ports. Not performing this step will result in unpredictable behaviors on the FCIP links. Note that in the case of the extension blade, only the blade needs to be power cycled and not the entire DC SAN/DC04 SAN Director chassis. Firmware migration considerations For units currently operating at Fabric OS 6.2.x, HP recommends that you use Fabric OS 6.3.0d or 6.3.1a or later prior to migrating to Fabric OS 6.4.0c. This avoids an RSCN issue with earlier 6.3.x versions. For units currently operating at Fabric OS 6.3.x, there are no special steps required to migrate to Fabric OS 6.4.0c. Firmware upgrade instructions IMPORTANT: HP recommends that you upgrade to Fabric OS 6.4.0c as soon as possible to take advantage of the fixes and new features. Upgrading to Fabric OS 6.4.0c is allowed only from Fabric OS 6.3.x. For more guidelines, see "Update recommendation" on page 5. To access the latest Fabric OS 6.4.0c firmware, configuration files, and MIB files, see the HP website: http://www.hp.com/support/downloads On the website: 1. Under Storage, select Storage Networking. 2. Select the link for the appropriate switch, select your product, and then select Cross operating system (BIOS, firmware, Diagnostics, etc.). 3. Select Firmware. HP StorageWorks Fabric OS 6.4.0c Release Notes 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74

The 2408 FCoE Converged Network Switch does not support nondisruptive HCLs. As a result, any
firmware upgrades are disruptive to the I/O through the switch. Similarly, a code load of DC SAN
Director or DC04 SAN Director with one or more DC SAN 10/24 FCoE blades disrupts traffic through
the blade.
If there are multiple node encryption groups (EGs) in a fabric, complete the firmware download on
one node at a time before downloading on another node.
Disable the ports in DC SAN Backbone Director Logical Switches that use 10 bit addressing mode
that have 8 bit areas in the range 0x70-0x8F before upgrading to Fabric OS 6.4.x. Otherwise
firmware upgrade fails with an error message. This step is necessary even if you do not plan to use
FC8-64 blades after performing firmware upgrade to Fabric OS 6.4.0. However, if areas 0x70-0x8F
are not in use, this step is not necessary. Use portAddress CLI to find out the areas in use within a
Logical Switch.
If Bottleneck detection feature is currently enabled on the switch running Fabric OS 6.3.x, you must
disable it before upgrading to Fabric OS 6.4.x; otherwise, frame drops may occur due to increased
Hot Code Load (HCL) time.
1606 Extension SAN Switch and DC SAN Director Switch Multiprotocol Extension blade must be
power cycled after upgrading from Fabric OS 6.3 to Fabric OS 6.4. This is necessary to load the
new FPGA image that enables IPv6 capability for FCIP links to the switch and the blade. This step is
mandatory even if IPv6 is not used on the FCIP ports. Not performing this step will result in unpredictable
behaviors on the FCIP links. Note that in the case of the extension blade, only the blade needs to be
power cycled and not the entire DC SAN/DC04 SAN Director chassis.
Firmware migration considerations
For units currently operating at Fabric OS 6.2.x, HP recommends that you use Fabric OS 6.3.0d or
6.3.1a or later prior to migrating to Fabric OS 6.4.0c. This avoids an RSCN issue with earlier 6.3.x
versions.
For units currently operating at Fabric OS 6.3.x, there are no special steps required to migrate to
Fabric OS 6.4.0c.
Firmware upgrade instructions
IMPORTANT:
HP recommends that you upgrade to Fabric OS 6.4.0c as soon as possible to take advantage of the
fixes and new features. Upgrading to Fabric OS 6.4.0c is allowed only from Fabric OS 6.3.x. For
more guidelines, see
Update recommendation
on page 5.
To access the latest Fabric OS 6.4.0c firmware, configuration files, and MIB files, see the HP website:
h
t
tp://w
w
w
.hp
.co
m/su
ppo
r
t/do
w
nloads
On the website:
1.
Under Storage, select
Storage Networking
.
2.
Select the link for the appropriate switch, select your product, and then select
Cross operating
system (BIOS, firmware, Diagnostics, etc.)
.
3.
Select
Firmware
.
HP StorageWorks Fabric OS 6.4.0c Release Notes
25