HP 4400 HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 62
Fixed in Fabric OS 6.4.0, Edit CUP Port - will not scan
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Closed defect summary Solution In a multi-circuit FCIP tunnel configuration with 1606 Extension SAN switch, or multiprotocol extension blade, circuit failover on 1 Gb tunnels may not fail over to other available circuits with two rate limited circuits. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Disable ARL configuration (use minrate and maxrate options on the tunnel and circuit create commands where min rate and max rate are the same values. Observed VE tunnel bounce after a hareboot on edge switch EX/VEXport (Integrated Routing) under heavy load. This is due to fspftimeout during hafailover resulting from neighbor switch disabling the port caused by the switch taking too long to recover. Fixed in Fabric OS 6.4.0 sfpshow displays incorrect information for static values of XFPs. Fixed in Fabric OS 6.4.0 Running Fabric OS commands on the default switch with virtual fabrics enabled, after performing multiple cfgenable commands with TI zones enabled, causes a No space left on device error, and no further Fabric OS commands can be executed. Fixed in Fabric OS 6.4.0 Enchancement to the firmware to have an easy single command to know Fixed in Fabric OS 6.4.0 the state of the encryption status. Unable to activate a new PDCM Matrix with Web Tools. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: Activate the same PDCM Matrix from WebTools, with "Active=Save Mode" checked from 'Edit CUP Port Connectivity Configuration' window. I2C read values of 0xFF and I2C NACK error case not properly handled Fixed in Fabric OS 6.4.0 causing Fabric Watch to report improbable/unpredictable SFP values. Multicast data traffic is not forwarded out of snooping mrouter port. Fixed in Fabric OS 6.4.0 The ipAdEntIfIndex values@ 1.3.6.1.2.1.4.20.1.2 must correspond to Fixed in Fabric OS 6.4.0 ifIndex values at 1.3.6.1.2.1.2.2.1.1. Fabric Watch reports that the switch is in Marginal status due to mar- Fixed in Fabric OS 6.4.0 ginal ports when no ports report errors. When running a third-party host scan, the http daemon (weblinker.fcg) Fixed in Fabric OS 6.4.0 terminates and restarts several times, causing a temporary management service interruption. "Bad zone config" message is given in the status message window of the zone admin module, when user creates and enables a zone configuration from non primary FCS switch. Proper error message should be given in this case. Fixed in Fabric OS 6.4.0 Virtual target edit operation [changing the LUN and enabling CHAP] Fixed in Fabric OS 6.4.0 makes the virtual target to disappear from the show. You may see virtual target going offline after an edit operation from WebTools with iSCSI. When Replicate configuration fails due to some of the parameters, DCFM does not list them in the summary message. Fixed in Fabric OS 6.4.0 62