HP 4400 HP StorageWorks Fabric OS 6.4.0c Release Notes (5697-0703, September 2 - Page 63
WebTools Does Not Copy Effective Zone to Defined Zone DB During
View all HP 4400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Closed defect summary Solution WebTools Does Not Copy Effective Zone to Defined Zone DB During Configupload, so Defined Zone will not be updated. Fixed in Fabric OS 6.4.0 "Failed: Cannot start a transaction" error message is displayed when Fixed in Fabric OS 6.4.0 trying to delete the policies in open transaction. Fabric binding does not work in 239 domain mode in Interopmode 3 Fixed in Fabric OS 6.4.0 with FCR on 8Gb switches. EX port rejects it. 2408 FCoE switch floods FCP traffic on two ports to CNAs, and sends Fixed in Fabric OS 6.4.0 FCP traffic to the wrong CNA. Fabric OS diagnostics and POST do not illuminate any of the GEx portsduring initialization, making it difficult to determine visually if there is any issue with the LEDs for these ports. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: A diagnosing command is provided to test GEx LEDs. On activating/deleting Ipfilter policy, CAL.XML error message may be Fixed in Fabric OS 6.4.0 given in WebTools. Need to block user from manually failback to EE when switch is disabled. Fixed in Fabric OS 6.4.0 F Port mode Top talker monitor and EE monitor may not show the counters reliably after the fid change. Fixed in Fabric OS 6.4.0 Customer upgrades from v5.3.1a ---> 6.0.0 --> 6.1.1d and sees that Fixed in Fabric OS 6.4.0 the "bufsize" value for their custom setting in fabric watch was changed. The port mirroring "resource not available" error must be clarified on the CLI interface for the user. Fixed in Fabric OS 6.4.0 BMD core file was generated during the overnight HA reboot test on Fixed in Fabric OS 6.4.0 1606 extension SAN switch with FCIP and regular traffic. BMD crashed and core filed generated. EM computes total power usage using FRU headers instead of an internal power table. This causes multiple AP blades such as multiprotocol extension blade and 10/24 FCoE blade in a DC04 SAN director chassis to not power up when supplied with 120 VAC power. Fixed in Fabric OS 6.4.0 Fabric Merge/Segmentation indication - 0xfe is not triggered when E- Fixed in Fabric OS 6.4.0 port enabled/disabled in interopmode 2 for Brocade SMIA project. After configdefault on a standalone 8/24 SAN switch (also seen on 8/80, 4/32B and 4/256), unable to upload/restore its configfile in IM2, post message 'Failed to clear defzone mode' rc -1, err 0, msg. Fixed in Fabric OS 6.4.0 Workaround prior to upgrade: After configdefault is issued, enable the switch, then disable the switch and issue configdown. This will complete the process successfully. WebTools zone admin page may not automatically refresh, when a zoning configuration is enabled from McDATA switch. Fixed in Fabric OS 6.4.0 In WebTools CEE tab configuration changes are not logged in the log Fixed in Fabric OS 6.4.0 window. HP StorageWorks Fabric OS 6.4.0c Release Notes 63